JM Test Systems Product and Services Catalog Vol. IV 2024
ELECTRICAL TEST
HIPOTS / VLF TEST SETS (AC)
HIGH VOLTAGE VLF-28CM 28kV LOW FREQUENCY AC HIPOT TESTER
• Input: 120 volts, 60 Hz, 5 A peak, 2.5 A average,50/60 Hz, 3A peak, 2A average • Output: 0 - 28 kVac peak, 0.1 Hz, sinusoidal • Duty: Continuous • Load Rating: 0.4 µF • Metering: Voltmeter: -30 - 0 - +30kVac • Charging Current meter: 0 - 50 mA peak • HV Cable Output: Shielded output cable - 20 ft. (6m)
CALL JM FOR PRICING
Standard Accessories Include: Rugged case, shielded EPR output cable 20ft Dimensions: 15x11.5x22” Weight: 75 lbs HIGH VOLTAGE VLF-34E
HIGH VOLTAGE VLF-65E 65 kV VLF TESTER
34kV VLF TESTER
• Input 100 Vac - 265 Vac, 50 Hz/60 Hz, 20A max • Output VLF Sinewave: 0-65 kVAC peak/46 kVac rms @ 26 mA • VLF Square wave: 0-65 kVac peak @ 45mA • DC: 0 - ± 65 kV @ 45 mA • Duty: Continuous • Frequency: 0.1 Hz to 0.01 Hz in steps of 0.01 Hz • Load Rating: 1.0 μF @ 0.10 Hz @ 65 kV HVI’s newest entry to the Very Low Frequency test equipment market. Designed primarily for maintenance testing of Medium Voltage cable systems up to 35 kV.
• Input Voltage: 90 Vac – 265 Vac, 50 Hz/60Hz, 5A max. • HV Output: 0-34 kVac peak/0 24 kVac rms - Sinusoidal DC: +/- 34 kV • Frequency: 0.1 Hz to 0.01 Hz • Load Rating: 0.5 mF @ 0.1 Hz @ 34 kV,1.0 mF @ 0.05 Hz @ 34 kV,5.0 mF @ 0.01 Hz @ 34 kVtv, mF rating increases at lower voltages(Ex: 0.77 mF @ 0.1 Hz @ 22 kV peak) • Calculated: Capacitance, Resistance, Flashover voltage, Time to Failure
TOP SELLER !
Standard Accessories Include: Rugged Pelican like case with extendable handle and wheels, 20 ft (6m) high voltage RG8 test lead, 20ft (6m) U ground lead, software Dimensions: 19.7x12x18” Weight: 45 lbs
HIGH VOLTAGE VLF-6022CM 60kV @ 1kVa PORTABLE AC HIPOT TESTER
HIPOTS / VLF TEST SETS (AC)
• 60 kVac peak output makes this model suitable for testing cables rated up to 35 kV • High load capacity enables it to test up to approximately 10 miles of cable, depending on type • AC output tester with very low alternating current and polarity reversals every half cycle • Used to provide a go/no-go, or pass/fail, voltage withstand test • Input: 120 volts, 60 Hz, 15 A peak, 7.5 A average , (F) 230 volts, 50/60 Hz, 8A peak, 4A average (F suffix) • Output: 0 - 60 kVac peak, 0.1/0.05/0.02 Hz, sinusoidal • Load Rating: 1.1 µF @ 0.1 Hz 2.2 µF @ 0.05 Hz 5.5 µF @ 0.02 Hz • Load capacitance meter: 0 - 6 Microfarads • HV Cable Output: Shielded RG/8U output cable - 20 ft. (6m) & Interconnect cable - 10 ft. (3m)
Standard Accessories Include: 2 Piece unit with Controls & Portable AC Hipot, enclosed in a Rugged carrying case, shielded EPR output cable 20ft (6m), Interconnect cable 10ft (3m) Dimensions: (Controls)26x13x16” Weight: 31 lbs (Hipot Unit) 15x15x16.5” Weight: 120 lbs
CALL JM FOR PRICING
**PRICES ARE SUBJECT TO CHANGE**
JMTEST.COM • 800.353.3411
64
Made with FlippingBook Ebook Creator