2018 Marathon Motors Catalog
BUILT TOGO THE DISTANCE.
COMMERCIAL & INDUSTRIAL MOTOR SOLUTIONS
GET MORE COMMERCIAL & INDUSTRIAL MOTOR SOLUTIONS FROM TWO INDUSTRY-LEADINGBRANDS THAT ARE BUILT TOGO THE DISTANCE.
PERFORMANCE, POWER AND PRICE. YOU GOT IT. You don’t just need a motor. You need the right frame, mounting, shaft, and output. By combining the best of Marathon ® brand motors with the finest Century ® brand motors, you have more ways to find the perfect combination of performance and power.
THEBESTTECHNOLOGIESOF TWOLEADINGBRANDSBRINGYOU 30%MORE SOLUTIONS.
For more than 100 years, Marathon ® and Century ® brand motors have kept the commercial and industrial marketplace in motion, not to mention millions of institutional and residential motor applications that efficiently convert power to motion to keep the world moving. If it moves, or moves you, don’t be surprised if our commercial and industrial brands are at the center of it all.
Whether you specified Marathon brand or Century brand motors in the past, today you have more than 5,000 stock options. Most are in-stock, ready to keep you up and running.
1903 Century company founded
1905 First dual voltage single phase motor
1913 Marathon company founded
1914 Founders design the 1/4 HP washing machine motor
1914 First
fractional HP motor makes house- hold refrig-
eration possible
For Terms & Conditions of Sale, see the footer area on the home page of www.regalbeloit.com. Products in this catalog comply with EISA, SMR (Small Motor Rulemaking) and SMR2 Energy Legislative Mandates.
CONTENTS
GENERAL INFORMATION I
04 I
APPLICATION INFORMATION I
14 I
VARIABLE SPEED INFORMATION I
20 I
SINGLE PHASE I
24 I
OURALLNEWCATALOG ISEASYTOUSE ANDHELPSYOUSELECT THE RIGHT MOTOR—FASTER. Now offering more motor solutions, more motor applications Finding the right motor is simplified
GENERAL PURPOSE THREE PHASE I
39 I
SEVERE DUTY I
73 I
EXPLOSION PROOF I
83 I
MEDIUM VOLTAGE I
89 I
INVERTER DUTY “MAX” FAMILY I
91 I
PMAC I
98 I
PMDC I
100 I
IEC I
104 I
BRAKE MOTORS I
107 I
FARM/AGRICULTURE I
110 I
WASH DOWN DUTY ® MOTORS I
121 I
PUMP MOTORS I
136 I
HVAC/AIR MOVING I
170 I
OEM REPLACEMENTS I
207 I
DEFINITE PURPOSE I
215 I
MODIFICATIONS I
226 I
KITS & ACCESSORIES I
237 I
INDEX I
259 I
NEW IN THIS CATALOG CENTURY ® COMMERCIAL AND INDUSTRIAL MOTORS FRAME SIZES FROM 48–449T SYMAX ® -I PMAC 3-PHASE CONDENSER FAN MOTOR (SYMAX™ AND SYMAX-I™ INVERTER) 3-PHASE CONDENSER FAN
30 % MORE SOLUTIONS
5 , 000 STOCK OPTIONS
MOTORS WITH BCP (BEARING CURRENT PROTECTION) THREE PHASE BRAKE MOTORS LINE EXTENSION SINGLE PHASE HAZARDOUS DUTY ® DIVISION 1 EXPLOSION PROOF MOTORS (GROUP E) GLOBETROTTER ® MOTOR 213-449 Frame:
1915
1916 First company
1927 First dual voltage polyphase motors
1928 First rubber mounted cradle base
IP55 and Div II—TEFC Rolled steel ODP up to 365 frame TEAO COOLING TOWER, IP56
First totally- enclosed fan-cooled motor
to use dynamic rotor balancing
(cushion base)
BLUEMAX ® MOTOR, 1 TO 350HP WITH BCP INSTALLED VERTICAL P-BASE CRUSHER DUTY 16HP ODP CROP DRYER
E-TOOLS MATCHED TO THEWAYYOUWORK
Our comprehensive product offering is instantly visible online, not to mention in the palm of your hand New websites are gearing up to provide lightning-fast product comparisons Finding and specifying Marathon ® and Century ® brand motors will never be the same, whether you’re behind a desk or in the field
EASY SEARCH ONLINE CATALOG
DISTRIBUTOR LOCATORS
SERVICE CENTER LOCATORS
360° PRODUCT VIEWS
COMPETITOR CROSS REFERENCES
VIDEO LIBRARIES
LITERATURE LIBRARIES
MOTOR DRAWINGS
ENERGY CALCULATORS
MOBILE APPS MOTORAID MEBIZ
1940 Current plant
1956 First fractional HP motor designed for swimming pool pumps
1960 1/20 HP through 3500 HP motors introduced
1976 First Energy Efficient Polyphase Integral HP motors
1981 First two-speed motor, solid state switch with UL approval
1986 Marathon ® XRI ® product line introduced— lead- ing the industry in NEMA Premium ® efficiencies
is constructed
95% of the motors installed in a major Panama Canal upgrade were Marathon ® motors
NEMA Premium is a trademark of National Electrical Manufacturers Association. All Rights Reserved.
MODIFICATIONS AT THEWAREHOUSE
RESIDENTIAL VENTILATION AND LEISURE PUMPMOTORS WILL HAVE THEIR OWN CATALOG. In the ongoing quest to serve you better and match product to application, residential HVAC/R and pool and spa motors will have their own catalog. You’ll still find Commercial & Industrial pump motors in this catalog, but there’s no sense in thumbing through hundreds of solutions that—while they deliver brilliantly—aren’t
ENSURE CUSTOMSOLUTIONS FASTER. There is no one size motor that fits all applications That’s why we’ve expanded our modifications offering on most models Some modifications can be made and shipped same day while others take a day or two, but the line-ready motor solution you need will be ready to work
CHANGING FROM BALL TO ROLLER BEARINGS
ADDING SHAFT GROUNDING RINGS
geared for your applications. Watch for new residential motor catalogs soon, and more convenient organization online.
RE-NAMEPLATING
ADDING A C-FACE
THERIGHTMOTOR. THEOPTIMAL FIT.
ADDING AN ENCODER
Q&A
THEPERFECTSOLUTION. MORE CHOICES FROM TWO LEADINGBRANDS.
YOU’LL HAVE QUESTIONS. WE’LL HAVE ANSWERS. As you become familiar with specifying and buying commercial and industrial motors from this expanded offering, know that we’re ready to assist We’ve added more customer service professionals to guide you Your local field representative is also there for you, so lean on us
1997
2000 Blue Chip Series ® Severe Duty Explosion
2004 Regal acquires the commercial AC motor division of General Electric
2010 SyMAX ™ permanent magnet AC motor introduced, making Regal a leader in
2011 Regal acquisition of the A.O. Smith Electrical Products Company and the Century ® brand
2013 Regal
MAX GUARD ® insulation system introduced Marathon Electric is acquired by Regal
celebrates 100 years of the
Proof motor named Plant Engineering magazine product finalist
Marathon ® brand
permanent-magnet motor technology
TABLE OF CONTENTS
GENERAL INFORMATION
Page No.
Page No.
General Information 5 - 9 Nameplate Information 8 Model number nomenclature 9 Doing business with Regal 10 Operation, Maintenance and Storage 11 Motor Search on REGALBELOIT.COM 12 Service and Warranty 13 Application Information 11 - 18 Agency Information 14 Mechanical and Electrical considerations 15 Hazardous Duty ® overview 16 Terminology 18 Formulas and Conversion factors 19 Variable Speed Information Guidelines for general purpose motors on VFD 20 Application considerations 21 NEMA ® MOTORS (AC Induction) General Purpose Single Phase (NEMA Service Factor) Dripproof Rigid Base 24 Extended Thru-Bolt, Split Phase, Steel endshield 25 Rigid Base ( Century ® ) 26 Rigid Base (1.0 Service Factor) 27 C-Face Footless 28 C-Face Footed (Rigid Base) 28 Totally Enclosed Rigid Base 30 C-Face Footless 32 C-Face Footed (Rigid Base) 34 C-Face Footed (Removable Base) - Four in One 36 Hazardous Duty Division 1 Explosion Proof, Class I and II, Groups C (as noted), D, F, G Motors Rigid Base and Resilient Base 37 C-Face Footless and C-Face Footed (Rigid Base) 38 Dripproof - USA Mandated Efficiencie s Rigid Base, 50 Hz, Standard Efficiency 225 Rigid Base, XRI ® Motors 39 Rigid Base, NEMA Premium ® Efficiency Motors - Century 44 C-Face Footless, XRI Motors 46 C-Face Footed (Rigid Base), XRI Motors 47 Rigid Base, Globetrotter ® Motors 48 Medium Voltage - XRI Motors 89 Totally Enclosed NEMA Premium Efficiency Motors Rigid Base, XRI Motors 52 C-Face Footless, XRI Motors 58 C-Face Footed (Rigid and Removable Base) - Four in One, XRI Motors 60 Rigid Base, Globetrotter Motors 63 C-Face Footless Globetrotter Motors 69 C-Face Footed (Rigid Base), G lobetrotter Motors 70 Medium Voltage Motors XRI 89 Car Wash/ Wet Environment / C-Face Footless, Stainless Shaft IP55, XRI Motors 73 Blue Chip Severe Duty, Cooling Tower, Rigid Base, IP56, BCP, XRI Motors 74 Blue Chip Series ® Severe Duty, Rigid Base, XRI Motors 75 Blue Chip Series Severe Duty IEEE-841, Rigid Base, XRI Motors 79 Medium Voltage, XRI 89 l I i General Purpose Three Phase
Division 1 Blue Chip Series Hazardous Duty, Division 1 Explosion Proof, Class I and II, Groups D, F & G Motors 83 Hazardous Duty, Division 1 Explosion Proof, Class I and II, Groups C,D,E (as noted) F & G . . . . . . . . . . . . . . . . . . . . . 84 Hazardous Duty, Division 1 Explosion Proof, Class I and II, Groups C,D, F,& G, C-Face Footless 85 Blue Chip Hazardous Duty, Division 1 Explosion Proof, Class I and II, Groups C (as noted),D,F & G 86 Black Max ® Vector Duty Explosion Proof, Class I and II, Groups C,D,F, & G, C-Face Footed (Rigid Base) 94 Blue Max ® 2000, Explosion Proof, with Encoder, C-Face Footed (Rigid Base), Class I and II, Groups C (as noted),D,F, & G 96 Hazardous Duty ® , Division 2/Zone 2 Totally Enclosed, Class I Motors Blue Chip Series, Severe Duty, Rigid Base, XRI Motors . . . 75 Blue Chip Series Severe Duty IEEE-841, Rigid Base 79 Rigid Base, IP55, Globetrotter 63 MicroMAX ® , Totally Enclosed, C-Face Footless and C-Face Footed (Rigid Base) 91 MicroMAX Plus, (with Encoder), Totally Enclosed, C-Face Footed (Rigid Base) 92 Black Max Vector Duty, Totally Enclosed, C-face Footed (Rigid Base) 93 Black Max, Explosion Proof, Class I and II, Groups C,D,F & G, C-Face Footed (Rigid Base) 94 Blue Max 2000 Vector Duty, Totally Enclosed, Rigid Base and C-Face Footed (Rigid Base) 95 Blue Max 2000, Explosion Proof, with Encoder, C-Face Footed (Rigid Base), Class I and II, Groups C (as noted),D,F & G 96 Blue Max 2000, Brake motor, Totally Enclosed, C-Face Footed (Rigid Base) 97 Blue Max Brakemotor, Totally Enclosed, C-Face Footed (Rigid Base Motors) 90 Medium Voltage 89 Inverter (Vector) Duty: “MAX”-series AC Variable Speed motors SyMAX - i PMAC Condenser Fan Motors 98 SyMAX ® PMAC Motors 99 SCR Rated, Totally Enclosed, C-Face Footed (Removable Base) 100 SCR Rated, Totally Enclosed, C-Face Footless and C-Face Footed (Removable Base) - Century 101 Wash Down, SCR Rated, Totally Enclosed, C-Face Footed (Removable Base) 102 Low Voltage, Totally Enclosed, C-Face Footed (Removable Base) 103 Totally Enclosed Globetrotter Motors - B3 mount 104 Globetrotter Motors - B5 and B14 (flange) mount 106 Flange Kits 243 Single Phase, Totally Enclosed, C-Face Footed (Removable Base) 107 Three Phase, Totally Enclosed, Rigid Base 108 Permanent Magnet DC IEC METRIC MOTORS (AC Induction) Brakemotors Explosion Proof NEMA Premium Efficiency Motors Permanent Magnet AC
Severe Duty NEMA Premium Efficiency Motors
Shaded items = New Items
4
NEMA and NEMA Premium are trademarks of National Electrical Manufacturers Association. All Rights Reserved.
TABLE OF CONTENTS
Page No.
Page No.
Condenser Fan/Heat Pump, PSC, Open Air Over, Thru-Bolt, Shaft Up or Horizontal . . . . . . . . . . . . . . . . . . . . 175 Condenser Fan/Heat Pump, Three Phase, Open Air Over, Belly Band/Resilient Ring, Shaft Up or Horizontal 179 Evaporative Cooler Motors 181 Exhaust Ventilator, Single Phase, Dripproof, C-Face Footless - Single and Two Speed 199 Fan & Blower - Capacitor Start, Dripproof, Resilient Base - Single and Two Speed 190 Fan & Blower - Direct Drive, PSC, Open Air Over, Belly Band Thru-Bolt, Double Shaft 184 Fan & Blower - Direct Drive, PSC, Open Air Over, Extended Thru-Bolt, 460 Volt 183 Fan & Blower - Direct Drive, PSC, Open Air Over, Resilient Ring 183 Fan & Blower - Direct Drive, PSC, Open Air Over, Resilient Ring, Thru-Bolt mount 182 Fan & Blower - Direct Drive, PSC, Open Air Over, Torsion Flex mount 183 Fan & Blower - Split Phase and Capacitor Start, Totally Enclosed, Resilient Base - Single and Two Speed 195 Fan & Blower - Split Phase, Dripproof, Rigid Base - Single and Two Speed 189 Fan & Blower - Split Phase, Resilient Base - Single and Two Speed 194 Fan & Blower - Three Phase, Dripproof, Resilient Base - Single and Two Speed 196 Fan & Blower - Three Phase, Dripproof, Resilient Base - Single Speed 198 Fan & Blower - Three Phase, Totally Enclosed Non Vent, Resilient Base 195 Fan & Blower, Adjustable Ring Mount 198 Furnace Blower - PDQ mount 198 Kiln Duty 220 ME-CAN-DO (Multi-Horsepower), Condenser Fan, PSC, TEAO, Thru-Bolt 205 ME-CAN-DO (Multi-Horsepower), Fan & Blower - Direct Drive, PSC, Open Air Over, Resilient Ring, Thru-Bolt 206 Oil Burner, PSC, 48M flange mount 200 Oil Burner, Single Phase, 48M and 48N flange mount - Century ® 202 Oil Burner, Split Phase and Capacitor Start, 48M and 48N flange mount 200 Oil Burner, Split Phase and Capacitor Start, 56C Footless 201 Oil Burner, Three Phase, C-Face Footless (see also Centrifugal Pump, Three Phase) 201 Pedestal Fan, PSC, TEAO, Yoke Mount 213 Refrigeration Fan - Single Phase . . . . . . . . . . . . . . . . . . . . . . . 203 Refrigeration Fan - Three Phase (see also Condenser Fan/Heat Pump, Three Phase) 203 Transformer Cooling Fan, TEAO, Single Speed, Rigid Base 204 Unit Heater Fan, PSC, TEAO, Resilient Base 204 OEM replacement aftermarket motors 207 Definite Purpose Motors Automotive Duty T-Frame: GM 7E-TA (Blue Chip Series ® Severe Duty IEEE-841, Rigid Base, XRI ® Motors 79 T-Frame: Ford EM-1 (Blue Chip Series, Severe Duty, Rigid Base, XRI Motors 75 Carwash Motor Severe Duty/Wet Environment, C-Face Footless, Stainless Shaft, IP55 73 Aggregate Duty Air Compressor 215 216
Brakemotors (continued)
Three Phase, Totally Enclosed, C-Face Footless 108 Three Phase, Totally Enclosed, C-Face Footed (Removable Base) 109 Blue Max ® 2000 Brakemotor, Totally Enclosed, C-Face Footed (Rigid Base) 97 Brake kits: Four-in-One and Black Max 244 Aeration Fan, Single Phase, TEAO, Rigid Base (see HVAC/Air Moving section) 170 Auger Drive, Single Phase or Three Phase, TEFC, N-Flange 112 Center Pivot Irrigation, Three Phase, TEFC, with Drip Cover 118 Cow Cooler Motors 116 Crop Dryer, Single Phase, Dripproof/Air Over, Rigid Base 117 Crop Dryer, Three Phase, Dripproof/Air Over, Rigid Base 118 Extra-High Torque Chore Motor ® , Single Phase, TEFC, Rigid Base Motor 111 Extra-High Torque, Farm Rated®, Single Phase, TEFC, Rigid Base or C-Face Footed 111 Fan - PSC, TEAO, Resilient Base-Thru Bolt - Variable Speed 114 Fan - Single Phase Capacitor Start, TEAO, Rigid/Resilient Base - High Efficiency 113 Fan - Single Phase, TEAO, Direct Drive-Thru Bolt 117 Fan - Single Phase, TEAO, Direct Drive-Thru Bolt - Single and Two Speed 114 Fan - Single Phase, TEAO, Resilient Base-Thru Bolt 115 Farm Building Direct Drive 116 Farm Rated Motors 120 Grain Stirring, Single Phase, TEFC, Rigid Base 113 High Torque, Single Phase, TEFC, C-Face Footed (Rigid Base) 110 High Torque, Single Phase, TEFC, Rigid Base 110 Incubator/Hatchery Vent 118 Instant Reverse Farm Motors 114 Milk Pump Farm Motors 119 Poultry Duty 116 Surge Pump Replacement 120 Zero Milk Tank Farm Motors 119 Aeration Fan (see also Farm/Ag Duty) 170 Attic Fan 171 Centrifugal Fan 171 Circulator Pump, Single Phase, Dripproof - see also Pump/Fluid Handling section 204 Commercial Condenser Fan/Heat Pump, PSC, Open Air Over, Belly Band, Shaft Up 177 Commercial Condenser Fan/Heat Pump, PSC, Open and Enclosed Air Over, Resilient Ring 176 Commercial Condenser Fan/Heat Pump, PSC, Open Air Over, Rigid Base, Shaft Up or Horizontal 174 Commercial Condenser Fan/Heat Pump, Three Phase, Open Air Over, Shaft Up or Horizontal, BCP 178 Condenser Fan, PSC, Enclosed Air Over, Resilient and Rigid Base Single and Three Phase 173 Condenser Fan, SyMAX-i PMAC Three Phase, Totally Enclosed Air Over 98 Condenser Fan, Three Phase, Air Over,Belly Band/Resilient Ring or Rigid Base, JuggerNaut 180 Condenser Fan/Heat Pump, PSC, Open Air Over, Resilient Ring, Thru-Bolt, All Angle 174 Condenser Fan/Heat Pump, PSC, Open Air Over, Rigid Base, Shaft Up or Horizontal 173 Condenser Fan/Heat Pump, PSC, Open Air Over, Thru-Bolt, Shaft Down 173 Condenser Fan/Heat Pump, PSC, Open Air Over, Thru-Bolt, Shaft Up or Horizontal 172
Farm Duty / Agricultural
GENERAL INFORMATION
HVAC motors (Air Moving)
General Motors and GM are believed to be trademarks or trade names of General Motors LLC and are not controlled by Regal Beloit Corporation. Ford is believed to be the trademark or trade name of Ford Motor Company and is not controlled by Regal Beloit Corporation. NEMA and NEMA Premium are trademarks of National Electrical Manufacturers Association. All Rights Reserved.
5
TABLE OF CONTENTS
Page No.
Page No.
GENERAL INFORMATION
Definite Purpose Motors (continued)
Jet Pump (single compartment) - See Centrifugal Pump 139 Jet Pump, Two-Compartment, Single Phase, Dripproof, C-Face Footless, 56C/56J 137 Jet Pump, Two-Compartment, Single Phase, Dripproof, C-Face Footed (Rigid Base), 56C/56J 137 Jet Pump, Two-Compartment, Single Phase, Dripproof, Square Flange 137 Jet Pump, Two-Compartment, Single Phase, Dripproof, C-Face Footless, 56C/56J - Century 138 Jet Pump, Two-Compartment, Single Phase, Dripproof, C-Face Footed (Rigid Base), 56C/56J - Century 138 Jet Pump, Two-Compartment, Single Phase, Dripproof, Square Flange - Century 138 Oil Well Pump 221 Special Direct Replacement Pump Motors - Capacitor Start, Drip Proof, Round or Square Flange 143 Sump Pump, Split Phase, Dripproof 136 Vertical Solid Shaft P-Base, Three Phase, Dripproof 166 Vertical Solid Shaft P-Base, Three Phase, Totally Enclosed 168 PowerWash TM XT Wash Down Duty ® , Single Phase, Rigid Base Motors 121 PowerWash XT Wash Down Duty, Single Phase, C-Face Footless Motors 121 PowerWash Wash Down Duty, Single Phase, C-Face Footed (Rigid Base Motors) 121 PowerWash XT Wash Down Duty, Three Phase, Rigid Base Motors 122 PowerWash XT Wash Down Duty, Three Phase, C-Face Footless Motors 123 PowerWash XT Wash Down Duty, Three Phase, C-Face Footed (Rigid Base Motors) 124 PowerWash XT Wash Down Duty Close Coupled Pump, JM, Rigid Base Motors 125 PowerWash XT Wash Down Duty Centrifugal Pump (Jet Pump), C-Face Footless, 56J Motors 125 PowerWash XT Wash Down Duty Centrifugal Pump (Jet Pump), C-Face Footed, 56J Motors 125 PowerWash XT Wash Down Duty Brakemotor C-Face Footed and Footless Motors 126 PowerWash SXT Wash Down Duty, Single Phase, C-Face Footed (Rigid Base Motors) 127 PowerWash SXT Wash Down Duty, Three Phase, Stainless, C-Face Footless Motors 128 PowerWash SXT Wash Down Duty, Three Phase, Stainless, C-Face Footed (Rigid Base Motors) 129 PowerWash SXT PLUS Wash Down Duty, Single Phase, Stainless/BISSC, C-Face Footless Motors 130 PowerWash SXT Wash Down Duty, Single Phase, Stainless/BISSC, C-Face Footed (Rigid Base Motors) 130 PowerWash SXT PLUS Washdown Duty, Three Phase, Stainless/BISSC, C-Face Footless 131 PowerWash SXT PLUS Wash Down Duty, Three Phase, Stainless/BISSC, C-Face Footed (Rigid Base Motors) 132 PowerWash SXT PLUS Wash Down Duty, Three Phase, Closes Couple Pump JM (Rigid Base Motors) 133 PowerWash SXT PLUS Wash Down Duty, Three Phase, C-Face Footed (Rigid Base) Brake Motors 133 PowerWash SXT PLUS Wash Down Duty, Three Phase, C-Face Footed (Rigid Base) IEC Motors 134 PowerWash Extreme Washdown Duty, Three Phase, Stainless/BISSC, C-Face Footless 135 Wash Down Duty ® - Painted and Stainless Steel
Cooling Tower Blue Chip Severe Duty, Cooling Tower, Rigid Base, IP55, XRI 73 Blue Chip Severe Duty, Cooling Tower, Rigid Base, IP56, BCP, XRI 74 Blue Chip Severe Duty, Two-Speed,Totally Enclosed, Three Phase, Rigid Base, IP55 217 Convection and Pizza Oven Motors 222 Instant Reversing Single Phase Capacitor Start and PSC, Dripproof and Totally Enclosed Dripproof and Totally Enclosed 219 Kiln Duty 220 Multi-Speed Two-Speed, One-Winding & Two-Winding, Variable Torque, Three Phase, Dripproof, Rigid Base . . . . . . . 218 Oil Well Pump 221 Pressure Washer Single Phase, Dripproof, Rigid Base and C-Face Footed (Rigid Base) 223 Single Phase, Totally Enclosed, Rigid Base and C-Face Footed (Rigid Base) 224 Carbonator Pump, Split Phase, Dripproof 136 Centrifugal Pump (Jet Pump), Single Phase, Dripproof, C-Face Footed (Rigid Base), 56J 139 Centrifugal Pump (Jet Pump), Single Phase, Dripproof, C-Face Footless, 56C/56J 139 Centrifugal Pump (Jet Pump), Single Phase, Totally Enclosed, C-Face Footless, 56C/56J 139 Centrifugal Pump (Jet Pump), Three Phase, Dripproof, C-Face Footed (Rigid Base), 56J 140 Centrifugal Pump (Jet Pump), Three Phase, Dripproof, C-Face Footless, 56C/56J 140 Centrifugal Pump (Jet Pump), Three Phase, Totally Enclosed, C-Face footed (Removable Base), 56J 141 Centrifugal Pump (Jet Pump), Three Phase, Totally Enclosed, C-Face Footless, 56C/56J 141 Centrifugal Pump (Jet Pump), Three Phase, Dripproof or Totally Enclosed, C-Face footless, 56C/56J - Century ® 142 Circulator Pump, Single Phase, Dripproof - see also HVAC/Air Moving section 204 Close Coupled Pump, JM, Single Phase, Dripproof, C-Face Footed (Rigid Base) 144 Close Coupled Pump, JM, Single Phase, Totally Enclosed, C-Face Footed (Rigid Base) 144 Close Coupled Pump, JP, Single Phase, Dripproof, C-Face Footed (Rigid Base) 145 Close Couple Pump, JM, Three Phase, Dripproof, C-Face Footed (Rigid Base) or C-Face Footless, NEMA ® Premium Efficiency 146 Close Couple Pump, JM, Three Phase, Totally Enclosed, C-Face Footed (Rigid Base) or C-Face Footless, NEMA Premium ® Efficiency 150 Close Couple Pump, JP, Three Phase, Dripproof, C-Face Footed (Rigid Base) or C-Face Footless, NEMA Premium Efficiency 154 Close Couple Pump, JP, Three Phase, Totally Enclosed, C-Face Footed (Rigid Base) or C-Face Footless, NEMA Premium Efficiency 158 Fire Pump, Three Phase, Dripproof, Rigid Base 161 Fire Pump, Three Phase, TEFC, Rigid Base 164
Pump motors (Fluid Handling)
6
NEMA and NEMA Premium are trademarks of National Electrical Manufacturers Association. All Rights Reserved.
TABLE OF CONTENTS
Index
PowerWash Extreme Washdown Duty, Three Phase, Stainless/BISSC, C-Face Footed (Rigid Base) 135 Woodworking/Power Tool 225 50 Hertz 225 Modifications through MOD Central 196 Accessory Kits 207 Wash Down Duty ® - Painted and Stainless Steel (Continued) Efficiency - SyMAX ® Permanent Magnet Motors 255 Applications - UlteMAX ® and NovaMAX ® Permanent Magnet Motors 256 “Specials are our Specialty” 257
Catalog to Model Number 259 Model to Catalog Number 288 Warnings and Cautions 305 NEMA ® MG-1 Table 12-11 EPAct Efficiencies 308 NEMA MG-1 Table 12 -12 NEMA Premium ® Efficiencies 309 NEMA Quick Reference Dimensional Chart Fold Out Footnotes Fold Out Blue Chip Series ® Product Line Comparison IBC IEC Quick Reference Dimensional Chart Fold Out
GENERAL INFORMATION
HAVE YOU TOURED THE NEW REGAL WEBSITE? REGALBELOIT.COM FEATURES: • In depth information about Regal ® brands and products
• Competitive cross-reference tool • Robust product information details • Rotating 360˚ views of products
• View products based on solution and application within a specific industry • Access to dimensional drawings, CAD files, connection diagrams and more
CUSTOMER SEARCH: Search for products by part number, by product family, by industry, by application, by brand, by solution, by cross reference, by configurator, with engineering tools and more It is a 360˚ model designed to guide you to the right item
INFORMATIONAL TOOL: The website is packed with information, data, industry facts and statistics
Regalbeloit com
7
NEMA and NEMA Premium are trademarks of National Electrical Manufacturers Association. All Rights Reserved.
GENERAL INFORMATION
GENERAL INFORMATION
MARATHON ® MOTORS Since 1913, the Marathon ® name has been recognized for engineering excellence, custom-designed products and an extensive product line of industrial quality motors. Available in all popular enclosures from 1/12 HP through 2500 HP and in a variety of mounting configurations. The unique Marathon motor designs provide more options to add accessories such as; blowers, brakes and encoders, to our motors. Our state-of-the-art lab facilities are equipped and staffed with the finest resources available to ensure successful utilization of our products. Finally, as the preferred supplier of motors to most of the top drive manufacturers in North America, we have what it takes to be a leader in understanding the interaction of drives as they are applied with AC induction motors.
WEBSITE AND E-COMMERCE Information can be accessed instantly, any time of the day on ME-business. Marathon motor customers can sign-up for ME-business by contacting their sales representative.
ME-business can be accessed through: www.regalbeloit.com .
• Stock availability • Order status
• Shipping information • Invoice information • Product features and performance data
MARATHON MOTOR NAMEPLATE INFORMATION HOW TO READ THE NAMEPLATE The nameplate is the key to selecting the proper replacement motor.
Underwriters Laboratories, Inc. UL Recognized Component Mark UL file # CE (Conformité Européene) Marking This mark signifies the motor complies with the European Low Voltage Directive. CSA Verification Mark - Complies with CSA’s Energy Efficiency Verification Service and their Standard C390 - C390 is the Canadian efficiency equivalent of EPAct. CSA Mark - Certified by the Canadian Standards Association CSA file # CC# - Compliance Certification Number as per assigned by the Department of Energy. Motors meeting EPAct efficiencies or higher will have this number.
®
4
3
1
2
6
5
12
8
10
9
7
11
16
17
15
13
14
20
18
19
33
32
22
21
23
24
26
25
27
28
29
30
31
Motor Specifications (Example)
Agency Symbols
18. MTH/YR MFG. - Month and year motor was manufactured 19. WT/LBS - Motor weight in pounds 20. WT/KG - Motor weight in kilograms 21. HZ - Input frequency of the power supply, usually 50 or 60 HZ 22. VOLTS - Voltage rating of the motor at the operating frequency 23. HP - Rated horsepower the motor will produce 24. KW - Rated output in watts 25. F.L. AMPS - The rated load current expressed in amps at nameplated horsepower with nameplate voltage and frequency 26. S.F. - Percentage of the rated horsepower the motor can safely operate at: Example: 1.15 SF (115% of rated HP) 27. PF / COS - Power Factor / Cosine is the ratio of actual power to the apparent power 28. RPM - Full load speed at rated frequency 29. NOM EFF - Average efficiency 30. SHAFT END BEARING - Manufacturer drive end bearing number 31. OPP. END BEARING - Manufacturer opposite drive end bearing number
1. MODEL - The ID number 2. DATE CODE - The month and year manufactured 3. MTG. - Mounting 4. FRAME - The size & mounting 5. PART NO. - Customer part number
6. SER. - Serial number 7. TYPE - Electrical type 8. DES. - Code by NEMA ® or IEC 9. PH - Electrical phase usually 1 or 3 10. INS CL - Insulation class 11. DUTY - Time rating under load 12. MAX AMB - The allowable surrounding air temperature 13. ENCL - Enclosure (i.e. TEFC) 14. RISE - The temperature rise over ambient expressed in degrees Celsius when the motor operates at nameplated HP or KW 15. IP - Inherent protection of the enclosure to solids and liquids as defined by IEC 34-5 16. IC - Inherent cooling 17. CODE - NEMA ® locked-rotor KVA
32. SHAFT END BRG - Drive end bearing size 33. OPP - Opposite drive end bearing size
8
NEMA is a trademark of National Electrical Manufacturers Association. All Rights Reserved.
GENERAL INFORMATION
HOWTO READ A MODEL NUMBER: Each Marathon ® motor carries a model number that can be used to define some of the motor’s physical and electrical characteristics.
5. ELECTRICAL TYPE Single Phase:
A = Permanent split capacitor B = Capacitor start, capacitor run C = Capacitor start, induction run N = Split phase start, capacitor run S = Split phase Three Phase: T = Three phase H = Inverter Duty/IEEE841 Inverter Duty V = Medium Voltage DC Power: E = Permanent Magnet DC 6. RPM OR SPEED AT 60 HZ (Fractional Only) 34 = 2-Pole, 3600 rpm 17 = 4-Pole, 1800 rpm 11 = 6-Pole, 1200 rpm 8 = 8-Pole, 900 rpm
Example (For Fractional): 1PC48C17D2000AP
This is a breakdown of the model on the nameplate:
GENERAL INFORMATION
1 P C 48 C 17 D 2000 A P 1 2 3 4 5 6 7 10 11 12
This is a breakdown of the model in the catalog:
48 C 17 D 2000 4 5 6 7 10
Example (For Integral): 2QA215TBDRA7076ALL
This is a breakdown of the model on the nameplate:
2 Q A 215T B D R A 7076 AL L 1 2 3 4 5 7 8 9 10 11 12
7. ENCLOSURE
This is a breakdown of the model in the catalog:
D = Dripproof E = Explosion proof, non-ventilated F = Totally enclosed, fan cooled G = Explosion proof, fan cooled O = Open P = Partial S = Semi-enclosed T = Totally enclosed, non-ventilated V = Wash Down, non-ventilated W= Wash Down, fan cooled
215T B D R A 7076 4 5 7 8 9 10
1. DATE CODE - Year of Manufacture
(Not shown in catalog listings.)
2. THERMAL PROTECTION (Not shown in catalog listings.)
UL Recognized Motor Protector
UL Recognized
Motor
Combination
Construction
8. FRAME CONSTRUCTION Integral Fractional L = Aluminum (Full Frame)
Automatic Reset
Automatic Reset
Automatic Reset
(where applicable)
Q S U
Yes
Yes
B = Rolled Steel - Sourced D = Stainless Steel - Sourced U = Frameless - Sourced
No No
No
Y = Aluminum (Full Frame)
Yes Yes
Z = Aluminum (High Mount Down Frame) H = Aluminum - Sourced R = Rolled Steel (Full Frame) W = Rolled Steel (Full Frame) X = Rolled Steel (High Mount Down Frame) B = Rolled Steel - Sourced S = Cast Iron (Full Frame) N = Cast Iron (Full Frame) P = Cast Iron (High Mount Down Frame) C = Cast Iron - Sourced D = Stainless Steel
W
#
Manual Reset
Manual Reset
Manual Reset
P Z X
Yes
Yes Yes
No No
No
None
None
None
V
No
Yes
# Motor protector combination is U.L. recognized only if motor is used in direct drive fan duty application, and is under locked rotor condition, or is running under no-load condition .
9. STYLE LETTER (A, B, C, etc. indicate redesign) 10. SEQUENCE NUMBER
3. DATE CODE - Month of Manufacturer (Not shown in catalog listings.)
11. MINOR MODIFICATION LETTER(S)
4. NEMA ® FRAME SIZE - (Integral motors - T and U designate standard shaft, TS and US designate short shaft)
Fractional - 1 letter; Integral - 2 letters 12. MANUFACTURING CODE - A code for the factory where the motor was manufactured.
9
NEMA is a trademark of National Electrical Manufacturers Association. All Rights Reserved.
GENERAL INFORMATION
GENERAL INFORMATION
HOW TO READ A MODEL NUMBER: Continued
Example (“harmonized” motor design) :
E. Stack Length
A - 5/8” F - 1-1/4” L - 1-7/8” B - 3/4” G - 1-3/8” M- 2.0” T - 3-1/4” C - 7/8” H - 1-1/2” N - 2-1/4” U - 3-1/2” D - 1.0” J - 1-5/8” P - 2-1/2” W- 4.0” E - 1-1/8” K - 1-3/4” R - 2-3/4” Q- Spec. S - 3.0”
A B C D E F G H I 5 KH 3 6 K G 142 – X
A. Rotating Device
F. Endshield Construction G & N - Aluminum K - Steel C - Cap/Can
B. Type of Winding KH - Split Phase
KC - Capacitor Start, Induction Run K - Polyphase KCP - Permanent Split Capacitor KCR - Capacitor Start, Capacitor Run
G. Sequence Number
H. Current Revision (blank if original)
C. Lamination Size
3 - 48 frame, 4 - 56 frame
I.
Type of Overload X - UL Auto running & locked rotor Y - UL Manual running & locked rotor S - UL Auto locked rotor T - Non-UL Auto running & locked rotor U - Non-UL Manual running & locked rotor V - Thermostat W - UL motor parts
D. Length of Frame 48 frame
56 frame
2 3 4 5 6 7 8 9
5.17 5.42
5.73 6.63
None
None
5.80 6.23 6.63 7.23
7.11
None
7.63 8.44
Spec.
Spec.
ORDERING INFORMATION When ordering, please include the model number, catalog number, description of the motor, quantity, shipping and billing instructions. For pricing of non-stock motors, or if you need assistance in selecting the proper motor, please contact your nearest Regal sales representative or local Marathon ® motor distributor. All prices and data are subject to change without notice. Stock Product Stock product can be returned for credit as defined herein. Equipment must be in original packaging, unused in “as shipped” condition and is limited to products currently maintained in stock inventory . The quantity returned can- not exceed normal stock quantity level. All motors returned must have date codes no older than 18 months from date of manufacture. The minimum restocking charge is 15% of the original net purchase price. Modified and build to order motors cannot be returned for credit. Return freight charges are the responsibility of the customer returning the motor for credit. No returns will be accepted without prior authorization. CANCELLATIONS AND RETURNS
NON-STOCK PRODUCT CANCELLATION POLICY: Cancellation charges for non-stock orders received and entered will be determined based on the percentage of completion in the engineering and manufacturing process, accounting for all costs plus a reasonable profit. Regal’s determination of the cancellation charges shall be conclusive. DISCOUNTS AND MULTIPLIERS Except as noted, all prices in this catalog are list prices. 200 and 575 volt 3 phase ratings utilize the same list price as 230/460 volt. NEMA ® short shaft (TS) utilize the same list price as standard shaft (T). Contact Regal for special bearing systems, including all requirements for sleeve or roller bearing. For your discount and multiplier, contact your local Regal sales representative or local Marathon ® motor distributor. MODIFICATION/ACCESSORIES See the Modification/Accessories sections for more informa- tion on modifications to create special motor variations.
10
NEMA is a trademark of National Electrical Manufacturers Association. All Rights Reserved.
GENERAL INFORMATION
STORAGE PROCEDURES In the event that long-term storage of motors is required, Regal recommends the following precautions and procedures. This information is also contained in “Installation, Operation and Maintenance Instructions” (SB181). A. Keep motors clean 1. Store indoors 2. Keep covered to eliminate airborne dust and dirt. 3. Cover openings for ventilation, conduit connections, etc., to prevent entry of rodents, snakes, birds and insects. B. Keep motors dry 1. Store in a dry area indoors 2. Temperature swings should be minimal to prevent condensation. 3. Space heaters are recommended to prevent condensation. 4. Treat unpainted flanges, shafts and fittings with a rust inhibitor. 5. Check insulation resistance before putting motor into service. C. Keep bearings lubricated 1. Once per month, rotate shaft several turns to distribute grease in bearings.
STOCK, NON-STOCK AND BUILD UP MODELS Standard motors listed in this catalog, as indicated with a check mark ( √ ) next to the catalog number, are normally in stock. There is no minimum order quantity or minimum billing charge associated with stock motors, unless stated otherwise in your quotation or agreement with Regal. Production of non-stock catalog models and all build-up models is subject to minimum order quantities or setup charges listed below. 48-140 Frame = 24 piece minimum 180-250 Frames = 5 piece minimum or $250 set up/model 250-320 Frames = 5 piece minimum or $300 set-up/model Build-up motors must be thoroughly described at time of order, and/or associated with a formal quotation issued by Regal. Inclusion of product features for similar motors documented in this catalog should not be assumed. SERVICE For service on any Marathon ® motor, contact your nearest Regal authorized service station. For a complete listing of all domestic and foreign service stations, refer to www. regalbeloit.com. OPERATION AND MAINTENANCE For information on operation and maintenance, please consult the manual or card shipped with your new motor. Additional copies of “Installation, Operation & Maintenance Instructions” (brochure SB181) are available upon request or through our website, www.regalbeloit.com.
GENERAL INFORMATION
2. If unit has been stored more than one year, add grease before start-up (refer to lubrication procedure).
DIMENSION DRAWINGS See regalbeloit.com or request certified drawings through your Regal sales engineer, representative or local Marathon motor distributor.
11
GENERAL INFORMATION HOWTO FIND A MOTOR ON REGALBELOITCOM
GENERAL INFORMATION
1 From our homepage, enter in the Marathon ® Catalog number or Model number in the search box Hit enter
2 Then click on Model number in results window (Note: If you already have a Marathon motor and are looking for the performance data, make sure the model number off the nameplate is what you use for your search Ex 056H17T5301)
3 The motor model details page will appear Scroll down on the motor details results page where there are options to print dimensional drawings and connection diagrams in PDF format for the motors Under the Technical Data section, click on the link, Certification Data Sheet
4 The results will look similar to the example shown to the right for the Marathon MaxGuard ® motor, model # 405THFS8036 It’s that easy!
12
GENERAL INFORMATION
WARRANTY Regal warrants Fractional and Integral motors to be free from defects in materials and workmanship and to conform to Regal’s written specifications. For a copy of our Standard Terms and Conditions of Sale, please visit http://www.regalbeloit.com.
Warranty Period from Date of Manufacture*
Warranty Period from Date of Installation*
MOTOR TYPE
GENERAL INFORMATION
12 12 24 24 36
18 18 30 30 42
Standard warranty for any product not shown below
Medium voltage
EPAct compliant (aluminum, steel & cast iron frame) Blue Chip Series ® motor severe duty explosion proof
Blue Max ® motor, Black Max ® motor, & microMax™ motor inverter duty All NEMA Premium ® incl. ODP, Blue Chip Series motor, severe duty, explosion proof, etc.
36
42
60 60
66 66
U-Frame automotive duty motor Blue Chip Series motor IEEE-841
* Warranty period shown is in months, and is valid for whichever period expires first. Note: Brake discs are considered a normal maintenance item and are not covered under warranty. For more information on Regal’s warranty policy, refer to the “Terms and Conditions of Sale.” See the footer area on the home page of www.regalbeloit.com.
SUBMITTAL CHARGE SCHEDULE
SUBMITTAL DATA Mechanical and electrical submittal data is available on many stock catalog motors through our website www.regalbeloit.com by following the three steps listed on the next page. All other submittal data is available upon request when accompanied by a purchase order for the specified motor, subject to the following additional charges.
TYPE ELEMENTS
NET/EA
Nameplate data Motor characteristics Performance data Outline drawing External connection diagram
No-Charge
BASIC (.PDF format)
Add for .dxf or .dwg format
$25
All “BASIC” elements, tailored to specific order.
$75
BASIC-PLUS (.PDF format)
“Cut sheets” of installed accessories Add for .dxf or .dwg format
$25
Speed/Torque curve
$50
Torque capability curve
$50
Commercial (end of line) test results (not available for West Plains motors)*
$50
ADDITIONAL ITEMS (.pdf formats)
Certificate of conformance
$100
Thermal damage curve (48-326T frame)
$500 + cost of additional motor $1500 + cost of additional motor
Thermal damage curve (364T-6805 frame)
* Does not imply retesting
13
NEMA Premium is a trademark of National Electrical Manufacturers Association. All Rights Reserved.
APPLICATION INFORMATION
AGENCY LISTINGS UL and CSA Marathon ® Fire Pump and Explosion Proof motors are UL listed. Other motor types are UL recognized, including models with inherent overheating protection as noted (i.e. thermally protected models). Marathon motors are also CSA Certified for both explosion proof and non-explosion proof enclosures.
ATmospheres EXplosibles (ATEX Directive) Mandatory by law, the European Union (EU) Directive 94/9/EC requires that electric motors for use in explosive atmospheres carry the CE mark, notified body identifier, Ex symbol, equipment group and category, plus the date code. See “European Installations” for additional details, located on the next page. National Electrical Manufacturers Association (NEMA ® ) Marathon motors are manufactured in accordance with all applicable areas of NEMA standards in MG1-2006. When applied in accordance with the “Guidelines for application of three phase motors on variable frequency drives”, Marathon motors are in full compliance with NEMA MG1-2006, Part 31, Section 4.4.2 , as pertaining to voltage spikes. 460 volt motors must withstand voltage spikes of up to 1426 volts; 575 volt motors must withstand spikes up to 1788 volts. See “Insulation Systems” for additional detail on this subject. COMMITMENT TO ROHS AND WEEE EUROPEAN DIRECTIVES European Directive 2002/95/EC “Restriction of Use of Certain Hazardous Substances” (RoHS) and Directive 2002/96/EC “Directives on Waste Electrical and Electronic Equipment” (WEEE) were enacted to control the amount of certain haz- ardous substances contained in products shipped into the E.U. Restricted substances include lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls and polybrominated dipheynl ethers. The scope of products covered, affecting motors, is: • Large household appliances • Small household appliances • IT and telecommunications equipment • Consumer equipment • Electrical and electronic tools (except large scale stationary and industrial tools) • Toys, leisure and sports equipment • Automatic dispensers The Directives do not currently apply to medical devices, monitoring and control instruments, spare parts for the repair or reuse of electrical and electronic equipment placed on the market before July 1, 2006 and most military and state security equipment. Regal worked closely with suppliers to assure that product falling within the scope of these Directives meets the specified levels of these substances. The Directives took affect July 1st, 2006; however, many products were converted in May and June. The products converted are motors in NEMA frame size 145 and below, both AC and DC motors with the following exceptions: • Sleeve bearing motors • Brake motors in 56-145 frame will have to be ordered specifically as RoHS compliant. • Some motors with specialty electro-mechanical components.
AC MOTORS Non-Explosion Proof
UL File No.
CSA File No.
Note 1
Note 2
APPLICATION INFORMATION NEMA ® 48-449 Frame All 5K type models numbers
E49747 E46035
LR2025
MC236833
NEMA 500 and 5000 Frame
–––
LR2025* LR2025 LR2025
IEC 63-90 Frame
E49747 E6312
Thermally Protected motors
Thermally Protected 5K motors E14133
MC236833
Insulation Systems
E37900
LR2025
Insulation Systems 5K motors E306343
MC236833
* Does not include coverage for use with VFD Explosion Proof N. America Division 1 / Zone 1
UL File No.
CSA File No.
Note 1
Note 2
NEMA 48 Frame
E12044 E12044 E12044
LR21839 LR47504 LR21839
NEMA 56-326 Frame NEMA 364-449 Fire Pump Motors
UL File No.
CSA File No.
Note 1
Note 2
NEMA 143-510 Frame ODP
EX5190
LR2025 LR2025 LR2025
NEMA 182-5011 Frame TEFC EX5190
IEC 80-355 Frame TEFC
EX5190
N. America Division 2 / Zone 2
Class I
UL File No.
CSA File No.
Note 1
Note 2
NEMA 48-449, 5000 Frame, totally enclosed, 3 Phase AC Induction NEMA 182-286 Frame, IEC 112- 180 Frame, PMAC NEMA 213-449 Frame, TEFC, Sourced
–––
LR21839
–––
LR21839
E12044
–––
European ATEX
Certificate No.
Zone 2 / Zone 22
NEMA 143-449 Frame, IEC 112-280 Frame Totally Enclosed, 3 Phase AC Induction
ITS 06 ATEX 45370
European ATEX
Certificate No.
Zone 2 / Zone 21/ Zone 22
IEC 80-355 Frame, TEFC, Sourced
DEMKO 17 ATEX 1836X
IECEx
Certificate No.
Zone 2 / Zone 21/ Zone 22
IEC 80-355 Frame, TEFC, Sourced PMDC MOTORS Non-Explosion Proof
IECEx UL 17.0014X
UL File No.
CSA File No.
Note 1
Note 2
NEMA Subfractional to145 Frame E49747 LR2025 Note 1: UL Certifications available online at www.ul.com, select "Online Certifications Directory" link, enter desired UL File No. Note 2: CSA Certifications available online at www.csagroup.org/services-industries/product- listing/, enter desired CSA File No. using six digit numerical format (e.g. 002025, 021839, etc.) Conformity Europeanne (CE) CE marking on the nameplates of Marathon motors is available upon request for most motors rated 600V or less. We do not apply the CE marking to explosion proof motors. The European “Low Voltage” Directive applies to electric motors. Contact a factory representative for details. Non-explosion proof micro- MAX ™ , BlackMax ® and BlueMax ® (TENV and TEFC) standard (catalog) models have the CE mark on the nameplate.
Continued on next page.
14
NEMA is a trademark of National Electrical Manufacturers Association. All Rights Reserved.
Made with FlippingBook - professional solution for displaying marketing and sales documents online