Magnetic Door Lock This delayed egress magnetic door lock can be used on perimeter exit doors and internal fire doors to block unauthorized exit and entry while providing a safe means of escape during a fire or other emergency. When someone attempts to exit through a protected door, an alarm will sound to alert staff before the door unlocks. The

Fall Management 101-114

“nuisance cycle” requires constant pressure on the door between 0-3 seconds to activate the “egress cycle.” Once the “egress cycle” is activated, the door remains locked for 15-30 seconds, giving staff time to respond to the unauthorized exit or, if during a fire or other emergency, unlocks to allow life saving egress. • NFPA Life Safety Code 101 Compliant • Deters unauthorized exit/entry • Door status indicator • Includes power supply • Can be used as a stand alone system or in conjunction with wandering detection systems

S P E C I F I C A T I O N S Lock Body:

10 1 ⁄ 2

"W x 2 3 ⁄ 8

"H x 1 5 ⁄ 8

"D

Mobility & Transfer 115-148

Armature:

7 1 ⁄ 4

"W x 2 3 ⁄ 8

"H

x 5 ⁄ 8

"D

Finish:

Anodized brushed aluminum

Door Status Output: Form “A” Contact, 500 mA@ 24 VDC Current: 525 mA @ 12 VDC 275 mA @ 24 VDC

Power:

12 or 24 VDC

Part No. Description 114706 Magnetic Door Lock, 0-3 second nuisance, 15/30 second egress (field selectable), 12 or 24 VDC

Holding Force:

1200 lbs

149-186

Beds & Room Supply

Assistive Devices 187-204

Electromagnetic Door Holders Ruggedly constructed and attractively designed two-part assembly with brushed zinc housing. Perfect for use with stairwell doors, room doors, exit doors or wherever instant closing of a door is necessary for safety or convenience. Can be configured to close any number of doors at the same time (additional hardware is required). Can be operated in conjunction with automatic fire alarm or sprinkler system, or with manual control. Wall units are available in flush or surface mounted versions. Swivel contact plate adjusts to any door angle using a nylon shock absorbing swivel ball.

1508-AQN5

205-228

Biomed & Respiratory

1505-AQN5

• Silent operation • Mounting hardware is included • Brushed zinc finish on housing • 120 VAC & 24 VAC/DC

25 lbholding force

Carts & Storage 229-237

Part No.

Description

Total

Plate

Projection

Dimensions

1509-AQN5

1 7 ⁄ 8

2 3 ⁄ 4

"W x 4 5 ⁄ 8 "W x 4 5 ⁄ 8 "W x 4 5 ⁄ 8

"H x 7 ⁄ 32

1509-AQN5 Door Holder, wall mount, flush mounted 1508-AQN5 Door Holder, wall mount, surface mounted 1505-AQN5 Door Holder, wall mount, flush mounted, short catch plate 1504-AQN5 Wall Mount, flush mounted, long catch plate

"

"D

4 1 ⁄ 16 2 9 ⁄ 16

2 3 ⁄ 4

"H x 2 7 ⁄ 16 "H x 13 ⁄ 16

" "

"D

2 3 ⁄ 4

"D

6 1 ⁄ 8 6 1 ⁄ 8

2 3 ⁄ 4

"W x 4 5 ⁄ 8

"H x 13 ⁄ 16 "H x 3 1 ⁄ 4

" "

"D

238-266

4 13 ⁄ 16

"W x 4 1 ⁄ 2

1501-AQN5 Floor Mount, single door

"D

1504-AQN5

Security & Maintenance

Parts For Electromagnetic Door Holders

Part No.

Description

CS2595-5

Catch Plate Kit for 1501, 1502, 1505, 1508 and 1509 series, includes catch plate assembly, back plate and screws Catch Plate Kit for 1504 series, includes catch plate assembly, back plate and screws

Repairs & Services 267-271

CS2598-5

1501-AQN5

*Shipped direct from the factory to you.