Hach Master Catalog 2025
Lab Electrochemistry • Probes Intellical Probes - ORP
64
MTC301 Laboratory Cable Length: 1mor3m Re fi llable Reference Element ±0.02 mV or 0.05%, whichever is greater 0 - 80 °C (32 - 176 °F) ±1200mV
MTC306 Laboratory Cable Length: 1m Metal RedOx Titration, Pt/Ref
MTC695 Laboratory Cable Length: 1m Metal RedOx Titration, Pt-Pt ±1200 mV (±200 µA)
MTC101 Laboratory Cable Length: 1mor3m Non-Re fi llable Gel Reference Element ±0.02 mV or 0.05%, whichever is greater 0 - 80 °C (32 - 176 °F) ±1200mV
MTC101 Rugged Field Cable Length: 5, 10, 15, or 30 m Non-Re fi llable Gel Reference Element ±0.02 mV or 0.05%, whichever is greater 0 - 80 °C (32 - 176 °F) Epoxy / Stainless Steel ±1200mV
Model
Electrode Type
Range
±1200mV
Accuracy
Temperature Range
0 - 80 °C (32 - 176 °F)
–10 - 80 °C (14 - 176 °F)
Sensor material
Epoxy
Epoxy
Epoxy
Epoxy
Flat disc sensor for easy cleaning.
Flat disc sensor for easy cleaning.
Flat disc sensor for easy cleaning.
Argentometric Silver nitrate) Titration
Imposed current Redox Titration
Special Features
Sample Depth
20mm
20mm
20mm
20mm
10mm
MTC10101 MTC10103
MTC10105, MTC10110, MTC10115, MTC10130
MTC30101 MTC30103
Prod.No.
MTC30601
MTC69501
Intellical Probes - ISE
ISECL181 Laboratory Cable Length: 1mor3m
ISEF121 Laboratory Cable Length: 1mor3m
ISENA381 Laboratory Cable Length: 1mor3m
ISENH318 Laboratory Cable Length: 1mor3m
ISENH418 Laboratory Cable Length: 1mor3m
ISENO318 Laboratory Cable Length: 1mor3m
Model
Parameter
Chloride
Fluoride
Sodium
Ammonia
Ammonium
Nitrate
Electrode Type
Non-Re fi llable Dritek Gel Reference Element
Non-Re fi llable Dritek Gel Reference Element
Re fi llable Reference Element
Non-Re fi llableGel Reference Element, Replaceable membrane 0.01 mg/L (5 x 10 -7 M) - 14 g/L (1 M) NH 3 -N ±0.02 mV or 0.05%, whichever is greater 5 - 50 °C (41 - 122 °F)
Non-Re fi llable Dritek Gel Reference Element
Non-Re fi llable Dritek Gel Reference Element
Range
0.1 mg/L (3 x 10 -6 M) - 35.5 g/L (1 M) Cl ±0.02 mV or 0.05%, whichever is greater
0.01 mg/L (5 x 10 -7 M) - 19 g/L (1 M) F ±0.02 mV or 0.05%, whichever is greater 5 - 50 °C (41 - 122 °F)
0.023 mg/L (1 x 10 -6 M) - 23 g/L (1 M) Na ⁺ ±0.02 mV or 0.05%, whichever is greater 0 - 50 °C (32 - 122 °F)
0.018 mg/L (10 -6 M) - 9 g/L (0.5 M) NH 4 -N ±0.02 mV or 0.05%, whichever is greater 0 - 50 °C (32 - 122 °F)
0.1 mg/L (7 x 10 -6 M) - 14 g/L (1 M) NO 3 -N ±0.02 mV or 0.05%, whichever is greater 0 - 50 °C (32 - 122 °F)
Accuracy
Temperature Range 5 - 50 °C (41 - 122 °F)
Sensor material Special Features
Epoxy
Epoxy
Zeonor™
Epoxy
Epoxy
Epoxy
Dry storage & fast response time. No replacement membranes.
Dry storage & fast response time. No replacement membranes.
Easy-to-replace membrane modules.
Dry storage & fast response time. No replacement membranes.
Dry storage & fast response time. No replacement membranes.
Sample Depth
26mm
26mm
26mm
26mm
26mm
26mm
Prod.No.
ISECL18101, ISECL18103, ISECL181AP*
ISEF12101, ISEF12103, ISEF121AP*
ISENA38101, ISENA38103, ISENA381AP*
ISENH318101, ISENH318103, ISENH3181AP*
ISENH418101, ISENH418103, ISENH4181AP* ISENO318101, ISENO318103, ISENO3181AP* *AP=Application Package, includes probe and reagents
Made with FlippingBook - Online catalogs