Hach Master Catalog 2025

Lab Electrochemistry • Probes Intellical Probes - ORP

64

MTC301 Laboratory Cable Length: 1mor3m Re fi llable Reference Element ±0.02 mV or 0.05%, whichever is greater 0 - 80 °C (32 - 176 °F) ±1200mV

MTC306 Laboratory Cable Length: 1m Metal RedOx Titration, Pt/Ref

MTC695 Laboratory Cable Length: 1m Metal RedOx Titration, Pt-Pt ±1200 mV (±200 µA)

MTC101 Laboratory Cable Length: 1mor3m Non-Re fi llable Gel Reference Element ±0.02 mV or 0.05%, whichever is greater 0 - 80 °C (32 - 176 °F) ±1200mV

MTC101 Rugged Field Cable Length: 5, 10, 15, or 30 m Non-Re fi llable Gel Reference Element ±0.02 mV or 0.05%, whichever is greater 0 - 80 °C (32 - 176 °F) Epoxy / Stainless Steel ±1200mV

Model

Electrode Type

Range

±1200mV

Accuracy

Temperature Range

0 - 80 °C (32 - 176 °F)

–10 - 80 °C (14 - 176 °F)

Sensor material

Epoxy

Epoxy

Epoxy

Epoxy

Flat disc sensor for easy cleaning.

Flat disc sensor for easy cleaning.

Flat disc sensor for easy cleaning.

Argentometric Silver nitrate) Titration

Imposed current Redox Titration

Special Features

Sample Depth

20mm

20mm

20mm

20mm

10mm

MTC10101 MTC10103

MTC10105, MTC10110, MTC10115, MTC10130

MTC30101 MTC30103

Prod.No.

MTC30601

MTC69501

Intellical Probes - ISE

ISECL181 Laboratory Cable Length: 1mor3m

ISEF121 Laboratory Cable Length: 1mor3m

ISENA381 Laboratory Cable Length: 1mor3m

ISENH318 Laboratory Cable Length: 1mor3m

ISENH418 Laboratory Cable Length: 1mor3m

ISENO318 Laboratory Cable Length: 1mor3m

Model

Parameter

Chloride

Fluoride

Sodium

Ammonia

Ammonium

Nitrate

Electrode Type

Non-Re fi llable Dritek Gel Reference Element

Non-Re fi llable Dritek Gel Reference Element

Re fi llable Reference Element

Non-Re fi llableGel Reference Element, Replaceable membrane 0.01 mg/L (5 x 10 -7 M) - 14 g/L (1 M) NH 3 -N ±0.02 mV or 0.05%, whichever is greater 5 - 50 °C (41 - 122 °F)

Non-Re fi llable Dritek Gel Reference Element

Non-Re fi llable Dritek Gel Reference Element

Range

0.1 mg/L (3 x 10 -6 M) - 35.5 g/L (1 M) Cl ±0.02 mV or 0.05%, whichever is greater

0.01 mg/L (5 x 10 -7 M) - 19 g/L (1 M) F ±0.02 mV or 0.05%, whichever is greater 5 - 50 °C (41 - 122 °F)

0.023 mg/L (1 x 10 -6 M) - 23 g/L (1 M) Na ⁺ ±0.02 mV or 0.05%, whichever is greater 0 - 50 °C (32 - 122 °F)

0.018 mg/L (10 -6 M) - 9 g/L (0.5 M) NH 4 -N ±0.02 mV or 0.05%, whichever is greater 0 - 50 °C (32 - 122 °F)

0.1 mg/L (7 x 10 -6 M) - 14 g/L (1 M) NO 3 -N ±0.02 mV or 0.05%, whichever is greater 0 - 50 °C (32 - 122 °F)

Accuracy

Temperature Range 5 - 50 °C (41 - 122 °F)

Sensor material Special Features

Epoxy

Epoxy

Zeonor™

Epoxy

Epoxy

Epoxy

Dry storage & fast response time. No replacement membranes.

Dry storage & fast response time. No replacement membranes.

Easy-to-replace membrane modules.

Dry storage & fast response time. No replacement membranes.

Dry storage & fast response time. No replacement membranes.

Sample Depth

26mm

26mm

26mm

26mm

26mm

26mm

Prod.No.

ISECL18101, ISECL18103, ISECL181AP*

ISEF12101, ISEF12103, ISEF121AP*

ISENA38101, ISENA38103, ISENA381AP*

ISENH318101, ISENH318103, ISENH3181AP*

ISENH418101, ISENH418103, ISENH4181AP* ISENO318101, ISENO318103, ISENO3181AP* *AP=Application Package, includes probe and reagents

Made with FlippingBook - Online catalogs