VALVES
Excess Flow Valves
RegO Excess Flow Valves for Container Service
ĞƐŝŐŶĞĚ ĨŽƌ ŵŽƵŶƚŝŶŐ ŝŶ ƚŚƌĞĂĚĞĚ ĨƵůů Žƌ ŚĂůĨ ĐŽƵƉůŝŶŐƐ ŝŶ ĐŽŶƚĂŝŶĞƌ ŝŶƐƚĂůůĂƚŝŽŶƐ͘ dŚĞLJ ŵĂLJ ďĞ ƵƐĞĚ ĨŽƌ ĨŝůůŝŶŐ͕ ǁŝƚŚĚƌĂǁĂů Žƌ ǀĂƉŽƌ ĞƋƵĂůŝnjŝŶŐ ĂƉƉůŝĐĂƚŝŽŶƐ͘
APPROXIMATE CLOSING FLOWS*
VAPOR SCFH (PROPANE) 25 PSIG INLET 100 PSIG INLET
FOR USE WITH THIS TYPE OF COUPLING
INLET CONNECTION M. NPT
OUTLET CONNECTION NPT 1 1/4” Female
PART NUMBER
LIQUID GPM (PROPANE)
A8525
Half Full Half Full Half Full Half Full Half Half Full
1 1/4”
35 75
12,540 13,000 25,000 25,000 30,500 30,500 32,100 32,100 39,400 51,100 51,100
21,560 25,600 42,500 42,500 52,000 52,000 55,500 55,500 68,300 88,700
A7537L4F A7537N4 A7537N4F A7537P4 A7537P4F A7539R6 A7539R6F A7539T6 A7539V6 A7539V6F
2” 2” 2” 2” 2” 3” 3” 3” 3” 3”
2” Male and 1 1/4” Female 2” Male and 1 1/4” Female 2” Male and 1 1/4” Female 2” Male and 1 1/4” Female 2” Male and 1 1/4” Female 3” Male and 2” Female 3” Male and 2” Female 3” Male and 2” Female 3” Male and 2” Female 3” Male and 2” Female
125 125 150 150 150 150 200 250 250
A7539
88,700 * Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down.
RegO Excess Flow Valves for Vapor or Liquid for Half and Full Couplings
ĞƐŝŐŶĞĚ ĞƐƉĞĐŝĂůůLJ ĨŽƌ ĨŝůůŝŶŐ͕ ǁŝƚŚĚƌĂǁŝŶŐ Žƌ ǀĂƉŽƌ ĞƋƵĂůŝnjŝŶŐ ŝŶ ŚĂůĨ ĂŶĚ ĨƵůů ĐŽƵƉůŝŶŐ ŝŶƐƚĂůůĂƚŝŽŶƐ͘ /ĚĞĂů ĨŽƌ ĐŽŶƚĂŝŶĞƌ ƐĞƌǀŝĐĞ ǁŚĞƌĞ ǁĞůĚĞĚͲŝŶ ĚŝƉ ƉŝƉĞƐ ĂƌĞ ŶŽƚ ƉƌŽǀŝĚĞĚ͘ &Žƌ ǀĂƉŽƌ ƵƐĞ͕ ŵŽƵŶƚ ŝŶ ƚŚĞ ďŽƚƚŽŵ ŽƉĞŶŝŶŐ ǁŝƚŚ Ă ƚŚƌĞĂĚĞĚ ĚŝƉ ƉŝƉĞ͘ &Žƌ ůŝƋƵŝĚ ƵƐĞ͕ ŵŽƵŶƚ ŝŶ ƚŚĞ ƚŽƉ ŽƉĞŶŝŶŐ ǁŝƚŚ Ă ƚŚƌĞĂĚĞĚ ĚŝƉ ƉŝƉĞ͘
APPROXIMATE CLOSING FLOWS*
INLET CONNECTION M. NPT
OUTLET CONNECTION NPT
PART NUMBER
VAPOR SCFH (PROPANE) 25 PSIG INLET 100 PSIG OUTLET
LIQUID GPM (PROPANE)
A2137
2” ** 2” ** 3” *** 3” ***
2” Male and 1 1/4” Female 2” Male and 1 1/4” Female 3” Male and 2” Female 3” Male and 2” Female
50 70
10,000 14,000 26,500 32,700
17,000 25,000 46,000
A2137A
2139
125 160
2139A 57,200 * Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with with outlet down.
A2137A
** 1 1/4” F.NPT dip pipe connection *** 2” F.NPT dip pipe connection
RegO Excess Flow Valve for Pressure Gauges
ĞƐŝŐŶĞĚ ĨŽƌ ĐŽŶƚĂŝŶĞƌ ƵƐĞ ŝŶ ƉƌĞƐƐƵƌĞ ŐĂƵŐĞ ŝŶƐƚĂůůĂƚŝŽŶƐ ƚŽ ŵŝŶŝŵŝnjĞ ĞdžĐĞƐƐ ŐĂƐ ĚŝƐĐŚĂƌŐĞ ŝŶ ƚŚĞ ĞǀĞŶƚ ƚŚĞ ƉƌĞƐƐƵƌĞ ŐĂƵŐĞ ŝƐ ƐŚĞĂƌĞĚ͘
APPROXIMATE CLOSING FLOWS*
VAPOR SCFH (PROPANE) CONNECTION 100 PSIG INLET
INLET CONNECTION M. NPT
OUTLET CONNECTION F. NPT
PART NUMBER
WRENCH HEX FLATS
LIQUID GPM (PROPANE)
2884D 110 * Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with with out let down. 3/4” F. NPT 1 1/16” N/A 60