Crest Healthcare 2020 Catalog

Building Emergency Alarms & Speakers

Operations: 235 - 264

®

114575 page 251

Stopper II® Stopper II helps prevent false alarm situations without restricting legitimate alarms. Tamper-proof, clear Lexan® shield and frame fit easily over manual-pull fire alarm stations. When shields lifted to gain access to fire alarm, it sounds a piercing warning horn. Larger sizes and surface mounted pull stations can be accommodated with a spacer that adds 2" of depth. When installed with gasket, it provides weatherproofing for outside pull stations. Power source is 9 V battery (included). Remote powered unit available.

270A-SPO

STi1100 (Cover only, fire alarm not included)

Edwards® Fire Alarm Single-action, break-glass type initiating device, rated for 3 A, 125 VAC, non-code pull station. Part No. Description Price 270A-SPO Fire Alarm, SPST, 25.95 one normally open contact 270A-DPO Fire Alarm, DPST, 49.95 two normally open contacts P-027165 Glass Rod, 2 3⁄16 "L x 4 mm diameter 1.95

Part No. STi1100

Description

Price

Stopper II with horn, flush mount, back plate inside measures: 5 1⁄2 "W x 6 1⁄5 "H

106.95

with cover max depth of 3 1⁄5 "

Stopper II without horn, flush mount, back plate inside measures: 6 1⁄2 "W x 7"H

67.95

STi1200

with cover max depth of 3 1⁄5 " Gasket to make unit weatherproof

9.95

STi3002 STi3100

20.95

Spacer to surface mount large stations, adds 2 inches to overall depth

year guarantee against breakage of polycarbonate in normal use 3

STi-13020FR

Indoor/Outdoor Universal Stopper® Polycarbonate covers help protect devices such as dual action pull stations, keypads for entry systems, intercom stations, emergency buttons, electrical light switches, duplex plugs etc. The strong, durable construction takes the toughest knocks while it guards against accidental or intentional physical damage. • Gaskets included • Available with or without horn & flush or surface mount options

SS2400E

2104X

STi® Stopper Switches These aesthetically appealing low/high voltage push button switches provide both a normally open and normally closed switch closure.These switches can be used in a variety of ways, including door bypass, and security override. • Available in 2 styles: locking switch with key reset or momentary switch • Fits standard 1-gang electrical back box

Part No.

Description

Price 42.95

STi-13000NC

Universal Stopper, no horn, flush mount,

5 2⁄5 "W x 8 1⁄5 "H x 2 3⁄5 "D

Part No. SS2400E

Description

Price 68.95

48.95

STi-13200NC

Universal Stopper, no horn, surface mount

“Emergency Push Here”push button station with maintained

5 2⁄5 "W x 8 1⁄5 "H x 4"D

switch closure and key reset (2 keys included) “Exit Push”push button station with momentary

96.95

68.95

STi-13020FR

Universal Stopper, with horn, flush mount, fire label,

2104X

5 2⁄5 "W x 8 1⁄5 "H x 2 3⁄5 "D

switch closure

Replacement Glass Rods Glass Rods replace those used in most break-glass rod type fire alarms. Part No. Description Price 440492 Glass Rod, 3 1⁄8 "L x 3 mm diameter 1.95 107499 Glass Rod, 3 3⁄8 "L x 3 mm diameter 1.95 107500 Glass Rod, 3"L x 3 mm diameter 1.95 107503 Glass Rod, 2 1⁄8 "L x 5 mm diameter 1.95 107501 Glass Rod, 2 1⁄4 "L x 5 mm diameter 1.95 107502 Glass Rod, 3 1⁄4 "L x 5 mm diameter 1.95

SMOKE DETECTORS Exclusively Online at CrestHealthcare.com

107501

All listed prices and products are subject to change without notice. Crest is not responsible for photographic or typographical errors.

online: www.cresthealthcare.com | 2020 | R30

245