ARP Supply Vol. 3

Defrost Controls, Adjustable Timers & Terminators

Unit21

Electrolux & Frigidaire

GE & Hotpoint

Unit#3078024

THERMISTOR

DEFROST CONTROLS

Sub Zero Thermistor assembly used on Sub- zero® models.

Commercial Refrigeration Features heavy-duty, synchronous motor, adjustable defrost frequency/ duration and steel case with electrical knockouts in sides, back and bottom. Temperature range -35°F to 175°F. 60 Hz. 40A non-inductive @ 120V, 208V or 240V AC. UL listed.

Whirlpool & Maytag

Order No.

Replaces 4204150

Cooking & Gas Products

TH4150

Unit#2752001

Dishwasher, Disposer & Water Heater

Order No.

Switching NO / NC

Volts

COMPRESSOR TERMINAL REPAIR KITS

Time Initiated / Time Terminated

Three Wire

S804100 S804120 S804500 S804520 8043-20 8047-00 8047-20 S814100 S814120 S814500 S814520 8143-00 8143-20

120 240 120 240

1 / 2 1 / 2 1 / 1 1 / 1

Laundry

208 / 240

2 to 4 / 1 to 3

120

2 to 4 / 3 2 to 4 / 3

Refrigeration

208 / 240

For use on air conditioners and refrigeration units. Heat sensored brass construction. Contains brass cylindrical tube, stainless set screw, wrench and anti-arcing spacer.

Time Initiated / Temperature or Pressure Terminated

Fittings, Venting & Installation

Order No.

For Unit Sz. Tons

120 240 120 240 120

1 / 2 1 / 2 1 / 1 1 / 1

Gauge

TLC38 TLC310 TLC312

8

5+

10 12

3 to 5 1 to 3

Electrical

2 to 4 / 1 to 3 2 to 4 / 3 /1 to 3

208 / 240

Unit#4281019

Defrost Controls, Adjustable Timers & Terminators Unit#3078066 Drop-In DEFROST CONTROLS

Plumbing

Replaces SUPCO S814520. 120V/240V.

DEFROST TERMINATORS

Order No.

Property Maintenance

Desc.

M814520

Defrost control

Motors

Unit#3078044

ADJUSTABLE TIMERS

For temperature control in refrigeration, defrost, ice maker, heat pump, air conditioning and dehumidifer applications. Sealed construction. Features 24” leads.

HVAC/R

For use with defrost heaters, water heat- ers, indoor/outdoor lighting systems, motors and pumps. Features adjustable intervals, LED indicators, fast cycle button and timer reset connection. Includes (2) sets of contacts. Screws not included.

Order No.

Open Temp. °F

Close Temp. °F

Chemicals

L45 L50 L55 L60 L70

45 50 55 60 70 45 50 55 60

25 30 35 40 50 25 30 35 40

Charging, Recovery & Welding

Max. Switching Amps

Order No.

CL45 CL50 CL55 CL60

Volts

Max. Motor Switching HP

Test Equip., Tools & Service Acc.

EDT13

120 220

1 2

27 25

EDT13-20

This information is provided “as is” without warranty of any kind by any person, including without limitation, the owner and the publisher.