2020-2021 Purchasing Guide Volume 6

HVAC |

Air Conditioners

14 SEER R-410A Condensing Unit • Hail guard grilles with 3/8" spacing for extra protection • Galvanized steel cabinet, Copeland scroll compressor • Liquid line filter drier included • Easy Access service valves on all models • 10-year* limited parts and compressor warranty

Line Size 1 Liquid/Suction

Valve Size 2 Liquid/Suction

Max 3 Fuse

Equipment Weight (Lbs)

Product #

MFG #

Region Tons Nominal Btu

W x H x D

North & Southeast Regions 224800

NXA418GKA N & SE 1.5 18,000 23-1/8" x 24-13/16" x 23-1/8"

3/8" x 3/4" 3/8" x 3/4" 3/8" x 3/4" 3/8" x 7/8" 3/8" x 3/4" 3/8" x 3/4" 3/8" x 3/4" 3/8" x 7/8"

3/8" x 3/4" 3/8" x 3/4" 3/8" x 3/4" 3/8" x 7/8" 3/8" x 3/4" 3/8" x 3/4" 3/8" x 3/4" 3/8" x 7/8"

123

20A 20A 25A 30A 20A 20A 25A 30A

224802 224804 224806

NXA424GKA N & SE 2.0 24,000 25-3/4" x 25-5/16" x 25-3/4"

119

NXA430GKA N & SE 2.5 30,000 31-3/16" x 31-13/16" x 31-3/16" NXA436GKA N & SE 3.0 36,000 31-3/16" x 24-13/16" x 31-3/16"

151

134

Southwest Region 224820

N4A518GKA SW 1.5 18,000 25-3/4" x 25-5/16" x 25-3/4" N4A524GKA SW 2.0 24,000 25-3/4" x 32-1/16" x 25-3/4" N4A530GKA SW 2.5 30,000 31-3/16" x 31-13/16" x 31-3/16"

122 123

224822 224824 224826

151

N4A536GKA SW 3.0 36,000 31-3/16" x 35-3/16" x 31-3/16"

171

All Regions 224808

N48548GKA All N4A560GKA All

4.0 48,000 31-3/16" x 28-1/4" x 31-3/16"

3/8" x 7/8"

3/8" x 7/8"

182 197

35A

224810

5.0 60,000 31-3/16" x 31-13/16" x 31-3/16" 3/8" x 1-1/8"

3/8" x 7/8" 2

40A

14 SEER R-410A Heat Pump • Hail guard grilles with 3/8" spacing for extra protection • Galvanized steel cabinet, Copeland scroll compressor • Suction line accumulator factory installed • Integrated solid state control with time temperature defrost • Bi-flow filter-drier included for field installation • 10-year* limited parts and compressor warranty

Line Size 1 Liquid/Suction

Valve Size 2 Liquid/Suction

Max 3 Fuse

Equipment Weight (Lbs)

Product #

MFG #

Region Tons Nominal Btu

W x H x D

All Regions 224900

N4H418GKB All

1.5 18,000 23-1/8" x 35-1/4" x 23-1/8" 2.0 24,000 25-3/4" x 35-3/4" x 25-3/4" 2.5 30,000 31-3/16" x 31-13/16" x 31-3/16" 3.0 36,000 31-3/16" x 28-7/16" x 31-3/16" 4.0 48,000 31-3/16" x 28-7/16" x 31-3/16"

3/8" x 5/8" 3/8" x 5/8" 3/8" x 3/4" 3/8" x 3/4" 3/8" x 7/8"

3/8" x 5/8" 3/8" x 5/8" 3/8" x 3/4" 3/8" x 3/4" 3/8" x 7/8" 3/8" x 7/8" 2

166

20A 25A 30A 30A 40A

224902 224904 224906 224908 224910

N4H424GKB All N4H430GKB All

175

180

N4H46GKB All

201

N4H448GKB All N4H460GKB All

232

5.0 60,000 31-3/16" x 31-13/16" x 31-3/16" 3/8" x 1-1/8"

248

50A

1) Line sizes denoted for 25 ft line sets. For other line-set lengths or sizes, refer to the installation and operating instructions and/or the long line-set guidelines.

2) Installer will need to supply 7/8" to 1-1/8" adapters for suction line connections. 3) Must use time-delay fuses or HACR-type circuit breakers of the same size as noted. Notes Always check the rating plate for electrical data on the unit being installed.

Unit is charged with refrigerant for 15 ft of 3/8" liquid line. System charge must be adjusted per instructions. *To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Units not registered within 60 days will receive 5-Year Limited Warranty.

98

supplyHQ.com | Phone: 866.630.6747 | Fax: 866.631.6747 | Bilingual: 888.281.0255

Made with FlippingBook Learn more on our blog