Goodman ® Multiposition (Closet) Air Handler For R-22 Or R-410A Refrigerant - Fully Insulated Steel Cabinet - Power Supply Entry At Top - Low Voltage At Top Or Side - Direct Drive Blower - Transformer And Blower Time Delays - Equipped With Check Flowrater For Cooling Or Heat Pump Applications - Built-In Coil - Vertical Or Horizontal Composite Drain Pan - Built-In Filter Rack - Prewired For Electric Heat Kits (Sold Separately) - Ships Configured For R-410A Use, But Can Be Configured For R-22 Use With New Piston Or TXV - 208/230 Volt
PISTON R-410A WIDTH DEPTH HEIGHT MOTOR TYPE FILTER (W X H)
PART #
TON KW MAX FUSE LIQUID SUCTION PISTON R-22
MFG #
a 453211 | 1.5 - 2.0 25.0 15 Amps 3/8"
3/4" .055/.061 .051
17-1/2"
21"
45"
PSC
16 x 20" ARUF25B14
b 563024 | c 563033 | d 563034 | e 563035 |
2.5
15 Amps 3/8"
7/8"
.065 .065 17-1/2"
21"
53-7/16"
MPSC
16 x 20" ARUF31B14
3.0
15 Amps 3/8"
7/8"
.074 .072
21"
21"
53-7/16"
MPSC 19-1/2 x 20" ARUF37C14
4.0
15 Amps 3/8"
7/8"
.088 .080 24-1/2"
21"
53-7/16"
PSC
23 x 20" ARUF49D14
5.0
15 Amps 3/8"
7/8"
.090 .080 24-1/2"
21"
58"
PSC
23 x 20" ARUF61D14
| See Footnote
SmartComfort ® By Carrier ® Closet Mount For R-22 Or R-410A Refrigerant - Power Supply Entry at Top Low Voltage at Top or Side - Direct Drive Blower - Transformer and Blower Time Delays Equiped with Check Flowater for cooling or Heat Pump Applications - Built in Coil - Vertical composite Drain Pan - Built-in Filter Rack - Prewired For Electrical Heat Kits (Sold Seperatly) - Ships Configured for R-410A Use, But can be Configured For R-22 Use with New Piston Or TXV - 208/230 Volt
PART # TON KW MAX FUSE LIQUID SUCTION PISTON R-22 PISTON R-410A WIDTH DEPTH HEIGHT MOTOR TYPE FILTER (W X H)
MFG #
f 282864 | 1.5 0 15 3/8" g 282865 | 2.0 0 15 3/8" h 282866 | 2.5 0 15 3/8" i 282867 | 3.0 0 15 3/8" j 282868 | 4.0 0 15 3/8" k 701892 | 5.0 0 15 3/8"
5/8" NAEA20101TX NAEB40501TX 14-5/16" 22-1/16" 42-11/16" ECM 13 x 21-1/2" FEM4P1800AL
5/8" NAEA20101TX NAEB40501TX 14-5/16" 22-1/16" 42-11/16" ECM 13 x 21-1/2" FEM4P2400AL
3/4" NAEA20101TX NAEB40501TX 17-5/8" 22-1/16" 49-5/8" ECM 16-3/8" x
21-1/2" FEM4P3000AL
3/4" NAEA20101TX NAEB40601TX 17-5/8" 22-1/16" 49-5/8" ECM 19-7/8" x
21-1/2" FEM4P3600AL
7/8" NAEA20201TX NAEB40701TX 21-1/8" 22-1/16" 49-5/8" ECM 19-7/8" x
21-1/2" FEM4P4800AL
7/8" Not Applicable TXV Factory
Installed 21-1/4" 22-1/16" 53-3/8" ECM 19-7/8" x 21-1/2" FEM4X6000BL
| See Footnote
SmartComfort ® By Carrier ® Heat Kit AHU Easy Field Installation - Designed For Use With Closet Mount Fan Coils
PART #
BTU
VAC
KW
AMPS
MAX FUSE
MFG #
l 700197 m 700198 n 700199
17060
208 / 220
5
24.9
30
EHK05AKN
25591
208 / 220
7.5
36.1
45
EHK07AKN
32757
208 / 220
10
45.5
60
EHK10AKN