2020-2021 Purchasing Guide Volume 2

Air Handlers, Furnaces & Coils | HVAC

a-e

f-k

l-n

Goodman ® Multiposition (Closet) Air Handler For R-22 Or R-410A Refrigerant - Fully Insulated Steel Cabinet - Power Supply Entry At Top - Low Voltage At Top Or Side - Direct Drive Blower - Transformer And Blower Time Delays - Equipped With Check Flowrater For Cooling Or Heat Pump Applications - Built-In Coil - Vertical Or Horizontal Composite Drain Pan - Built-In Filter Rack - Prewired For Electric Heat Kits (Sold Separately) - Ships Configured For R-410A Use, But Can Be Configured For R-22 Use With New Piston Or TXV - 208/230 Volt

PISTON R-410A WIDTH DEPTH HEIGHT MOTOR TYPE FILTER (W X H)

PART #

TON KW MAX FUSE LIQUID SUCTION PISTON R-22

MFG #

a 453211 | 1.5 - 2.0 25.0 15 Amps 3/8"

3/4" .055/.061 .051

17-1/2"

21"

45"

PSC

16 x 20" ARUF25B14

b 563024 | c 563033 | d 563034 | e 563035 |

2.5

15 Amps 3/8"

7/8"

.065 .065 17-1/2"

21"

53-7/16"

MPSC

16 x 20" ARUF31B14

3.0

15 Amps 3/8"

7/8"

.074 .072

21"

21"

53-7/16"

MPSC 19-1/2 x 20" ARUF37C14

4.0

15 Amps 3/8"

7/8"

.088 .080 24-1/2"

21"

53-7/16"

PSC

23 x 20" ARUF49D14

5.0

15 Amps 3/8"

7/8"

.090 .080 24-1/2"

21"

58"

PSC

23 x 20" ARUF61D14

| See Footnote

SmartComfort ® By Carrier ® Closet Mount For R-22 Or R-410A Refrigerant - Power Supply Entry at Top Low Voltage at Top or Side - Direct Drive Blower - Transformer and Blower Time Delays Equiped with Check Flowater for cooling or Heat Pump Applications - Built in Coil - Vertical composite Drain Pan - Built-in Filter Rack - Prewired For Electrical Heat Kits (Sold Seperatly) - Ships Configured for R-410A Use, But can be Configured For R-22 Use with New Piston Or TXV - 208/230 Volt

PART # TON KW MAX FUSE LIQUID SUCTION PISTON R-22 PISTON R-410A WIDTH DEPTH HEIGHT MOTOR TYPE FILTER (W X H)

MFG #

f 282864 | 1.5 0 15 3/8" g 282865 | 2.0 0 15 3/8" h 282866 | 2.5 0 15 3/8" i 282867 | 3.0 0 15 3/8" j 282868 | 4.0 0 15 3/8" k 701892 | 5.0 0 15 3/8"

5/8" NAEA20101TX NAEB40501TX 14-5/16" 22-1/16" 42-11/16" ECM 13 x 21-1/2" FEM4P1800AL

5/8" NAEA20101TX NAEB40501TX 14-5/16" 22-1/16" 42-11/16" ECM 13 x 21-1/2" FEM4P2400AL

3/4" NAEA20101TX NAEB40501TX 17-5/8" 22-1/16" 49-5/8" ECM 16-3/8" x

21-1/2" FEM4P3000AL

3/4" NAEA20101TX NAEB40601TX 17-5/8" 22-1/16" 49-5/8" ECM 19-7/8" x

21-1/2" FEM4P3600AL

7/8" NAEA20201TX NAEB40701TX 21-1/8" 22-1/16" 49-5/8" ECM 19-7/8" x

21-1/2" FEM4P4800AL

7/8" Not Applicable TXV Factory

Installed 21-1/4" 22-1/16" 53-3/8" ECM 19-7/8" x 21-1/2" FEM4X6000BL

| See Footnote

SmartComfort ® By Carrier ® Heat Kit AHU Easy Field Installation - Designed For Use With Closet Mount Fan Coils

PART #

BTU

VAC

KW

AMPS

MAX FUSE

MFG #

l 700197 m 700198 n 700199

17060

208 / 220

5

24.9

30

EHK05AKN

25591

208 / 220

7.5

36.1

45

EHK07AKN

32757

208 / 220

10

45.5

60

EHK10AKN

WARNING : California Residents, this product contains chemical(s), which is/are known to the State of California to cause cancer and/or birth defects or other reproductive harm. Find more information by visiting hdsupplysolutions.com to review the specific product details.

461

3 EASY WAYS TO ORDER

MOBILE APP

1.800.431.3000

hdsupplysolutions.com

HVAC

Made with FlippingBook Publishing Software