METERS WITH ACCESSORY HEADS
DIGITAL STICK METER WITH NON-CONTACT VOLTAGE
A/C SUPERHEAT & SUBCOOLING HEAD Measures refrigerant
MILLIAMPS & MICROAMP ACCESSORY
pressure and temperature and calculates superheat or subcooling for R22 and R410A.
Auto-Ranging Analog Bar Graph Temperature Non-contact Votage Capacitance Rugged Case Hi-Voltage Indicators Auto Power Off Backlight True RMS Microamps Frequency
• Measures milliamps and microamps for flame diode test. Measures 4 to 20mA control circuits. • Includes flame diode adapter kit (AQK3). • Resolution: 0.1 for meters with 0.1mVDC. • Accuracy: DC: ±(1.0%rdg + 1dgt) AC: ±(1.5% + 2dgts). • Max current: 200mA AC or DC. Locke# T1772 AUA2 Milliamps & Microamp Accessory
• Display pressure • Display temperature • Display superheat
• Display subcooling • Select R22 or R410A. • Auto-off can be disabled for data logging. NEW FEATURES • Includes "T". • Now accepts K-type thermocouples. ATC1 included. • LED indicates when readings are stable. • Thermocouple calibration pot. • Atmosphere pressure calibration. Locke# T1656 ASX14 Superheat & Subcooling Head
Every HS30 series meter comes packaged inside the padded ANC1 4-pocket case. A 300AAC clamp head (ACH) is included. Just slide the clamp onto the top of the HS30 meter to read amps. Also included are deluxe silicone test leads, alligator clips, k-type thermocouple (HS33, HS35, HS36), battery (installed), operator’s manual, and RFM66 fuse (installed). Test Lead Solutions • Probe storage in the back • Removable probe tips for connection to most accessory heads. • Attach detachable probe tip directly into jack for easy and safe voltage testing. • Leads conveniently wrap around meter. Locke# T1450 HS36-K11 Digital Stick Meter T1462 RFM66(4) Fuse for HS-36
400A AMP CLAMP ACCESSORY
CARBON MONOXIDE HEAD & PUMP
The claw feature at the top of the clamp allows for quickly picking out the wire you need to measure and isolating it in the clamp. Once the current carrying conductor is isolated, the amperage is converted to mVAC for reading directly on the meter. The ACH4 works with the Fieldpiece “Stick” meter, EHDL1 Electronic Handle, DL3 Data Logger, the HG2 HVAC Guide® System Analyzer or any other digital multimeter (with mVAC range) connected by Fieldpiece ADLS2 detachable silicone leads or AHDL1 handle adapter. Locke# T1775 ACH4 400A Amp Clamp Accessory
ELECTRONIC HANDLE
T
Measures CO in air and finds sources. • Fast enough to locate CO source in “walk- around” test. • Three pin sensor for better performance. • Select averaging or normal for smoothing or fast response to change. • Range: 0 to 1000PPM (2000PPM with 5 minute max exposure time). • Initial accuracy: 0-15ppm ±5% reading ±1 ppm after zeroing;15-35ppm ±5% reading ±2 ppm after zeroing; 0-1000ppm ±5% reading ±5 ppm after zeroing. • Response time: <70sec to 90%of reading. • Operating temperature: 32 to 105 ºF. Locke# T1657 ACMK3 CO Head
| TOOLS
Converts Every Fieldpiece Accessory Head into a Stand Alone Meter Locke# T1457 EHDL1 Electronic Handle