2014 Locke Supply Co.
CH CIRCUIT BREAKERS
CH MAIn CIRCUIT BREAKER LOADCEnTERS Indoor NEMA 1 Locke# Main Breaker P6780 CH14B100 B 100 Amps LC 14 CKT Spaces Cover Type B
TYPE CH CIRCUIT BREAKERS-10,000 AIC 2 Pole Ground Fault Breaker; 120/240V AC
GROUnD FAULT CIRCUIT InTERRUPTERS 2 Wire; 120 Volts AC 10,000 AIC
P6782
CH22B100 C 100 Amps LC 22 CKT Spaces Cover Type C CH30B100 D 100 Amps LC 30 CKT Spaces Cover Type D 150 Amps LC 32 CKT Spaces Cover Type J 200 Amps LC 32 CKT Spaces Cover Type J CH42B200 K 200 Amps LC 42 CKT Spaces Cover Type K 225 Amps 42 CKT Spaces Cover Type K CH32B150 J CH32B200 J CH42B225 K
Locke# P4104
P3703
CHFGF115 15A CHFGF120 20A
P1373
P6868
Locke# P0908
20A
CH220GF
2 Pole
P6783
GFCI Breaker
P0909
30A
CH230GF
2 Pole
CH LOADCEnTER ACCESSORIES CHL125N 125A Main Lug Kit For Convertible LC 225A Main Lug Kit For Convertible LC CHL225N CH125RB Hold Down Kit For Backfed CH Breakers in MLO LCS CHHT Plastic Handle Tie For Use With Two Single-Pole CH Type Breakers CHPL Padlockable Lockdog For 1, 2, Or 3 Pole CH Breakers, Requires An Extra Space, Locks On Or Off, Goes Behind Deadfront CHMS Circuit Marking Strips CHSF2125 125A 2 Pole, Subfeed Lug Kit
P6784
GFCI Breaker
P0919
40A
CH240GF
2 Pole
P1655
GFCI Breaker
Locke# P6872
P6886
50A
CH250GF
2 Pole
GFCI Breaker
P6887
60A
CH260GF
2 Pole
P6879
GFCI Breaker
CH MAIn BREAKER LOADCEnTER NEMA 1 Contractors Packs. Includes Covers. Locke# Ampacity P6830 CH22B100V 100A
P6885
P9029
ARC FAULT CIRCUIT InTERRUPTERS
P6234
MCB LC, 22 Space, Indoor, 5 CH120, 1 CH230 MCB LC, 32 Space, Indoor, 5 CH120, 1 CH230 MCB LC, 42 Space, Indoor, 5 CH120, 1 CH230 CH32B200V 200A CH42B200V 200A
P6292
P6839
P1390
P6867
P6754 & P6755
| ELECTRIC Features: AFCI Technology, the heart of the Arc Fault Circuit Interrupter enables it to recognize the unique characteristics of an aring fault... resulting in tripping the breaker, thus interrupting the circuit. Locke# Ampacity P6754 CH115AF 15a Single Pole ARC-Fault Breaker for CH Style P6755 CH120AF 20a Single Pole ARC-Fault Breaker for CH Style *P6759 CH220AF 20a 2 Pole CH ARC Fault Commo Trip * These breakers are to be used on 2 circuits that share a common neutral. 2008 nEC COMPLIAnT ARC-FAULT CIRCUIT BREAKERS Locke# P6852 CHCAF115 15A CH Combination Type Arc-Fault P6853 CHCAF120 20A CH Combination Type Arc-Fault
P
CH LOADCEnTER COVERS Indoor NEMA 1
MAIn CIRCUIT BREAKER OUTDOOR NEMA 3R Locke# Ampacity P6829 CH8B200RF 200A MCB LC, 8 Space, Outdoor, Feed- Through Lugs P6828 CH14B100R 100A MCB LC, 14 Space, Outdoor P9025 CH22B100R 100A MCB LC, 22 Space, Outdoor P6746 CH30B100R 100A MCB LC, 30 Space, Outdoor P9026 CH22B125R 125A MCB LC, 22 Space, Outdoor P6728 CH32B200R 200A MCB LC, 32 Space, Outdoor P3705 CH42B200R 200A MCB LC, 42 Space, Outdoor
Locke# P6785
CH8 B F CH8 C F CH8 D F CH8 E F CH8 G F CH8 J F CH8 K F CH8 L F CH8 N F
B Style Cover C Style Cover D Style Cover E Style Cover G Style Cover J Style Cover K Style Cover L Style Cover N Style Cover
P6786 P3781 P3780 P3785 P6787 P6788 P6779 P6717
CSR MAIn BREAKER KIT Locke# P9028 CSR2200N 200A 2 pole Main Circuit Breaker 25KAIC For Conv LCs & Enclosed Breakers
Mai Office: 405-631-9701
816
Fax: 405-631-0585
Made with FlippingBook