VACUUM BREAKERS, REDUCING VALVES & CHECK VALVES

2" DOUBLE CHECK VALVE ASSEMBLY

PRESSURE VACUUM BREAKER ASSEMBLY

WATER PRESSURE REDUCING VALVE

Series 007 Double Check Valve Assemblies prevent the backflow of contaminated water into the potable water supply. It consists of a bronze 2 in body construction that is easy to maintain and service. Series 007 is ideal at referenced cross-connections identified as non-health hazard applications. Check with local inspection authorities for installation requirements. Maximum Working Pressure: 175psi Locke# M1276 0062427 2" Double Check Valve Assembly

Designed for installation on potable water lines to protect against backsiphonage of contaminated water into the potable water supply. Assembly shall provide protection where a potential health hazard exists. Locke# M1708 720A ½" Pressure Vacuum Breaker Assembly M1709 720A ¾" Pressure Vacuum Breaker Assembly M1710 720A 1" Pressure Vacuum Breaker Assembly M1712 720A 1½" Pressure Vacuum Breaker Assembly M1713 720A 2" Pressure Vacuum Breaker Assembly

Designed for installation on potable water lines to reduce high inlet pressure to a lower outlet pressure. The unitized replaceable cartridge reduces time involved with cleaning and maintenance. The direct acting integral bypass design prevents buildup of excessive system pressure caused by thermal expansion. The balanced piston design enables the regulator to react in a smooth and responsive manner to changes in system flow demand, while at the same time, providing protection from inlet pressure changes Locke# M1692 70 ½" Water Pressure Reducing Valve M1693 70 ¾" Water Pressure Reducing Valve M1694 70 1" Water Pressure Reducing Valve

AIR GAPS

Locke# M1278

0881378 1¼"-2" Air Gap

M

| MISCELLANEOUS

SPILL RESISTANT PRESSURE VACUUM BREAKER ASSEMBLY

1" SPILL RESISTANT PRESSURE VACUUM BREAKER ASSEMBLY

Designed for installation on indoor and outdoor point of use applications to protect against backsiphonage of contaminated water into the water supply. During start-up and operation a separate diaphragm seals the air inlet from the water supply preventing spillage. The assembly is designed for use under constant pressure and provides protection where a potential health hazard exists. Locke# M1700 460 1" Spill Proof Backflow Preventer

Maximum working water pressure 150 PSI Maximum working water temperature 180°F Hydrostatic test pressure 300 PSI Threaded connections ANSI B1.20.1 Replaceable thermoplastic modular cartridge. Spill resistant feature for indoor use. Locke# M1700 460XL 1" Spill Resistant Pressure Vacuum Breaker Assembly