2014 Locke Supply Co.
GAS VALVES
24 VOLT HOT SURFACE MODEL
Specifications: Electrical Rating: Pressure Regulator: Natural Gas:
24 VAC, 5 amps
Factory set @ 3.5" W.C. Factory set @ 11.0" W.C.
LP Gas:
Pilot outlet:
¼" tubing
Ambient temperature: -40° to 175° F Maximum inlet pressure: 7" W.C. - natural gas / 14" W.C. - LP Gas 24 VOLT HOT SURFACE IGNITION Reducer Bushings Included:
Locke#
Vendor# Factory Model
Inlet Size Outlet Size Pressure Regulator Setting
Capacity ¾" x ½"
L0396
720-051 7200-DER 1/2"
3/4"
UNI-KIT
150,000
1
720-052
24 VOLT STEP-OPENING/CONVERTIBLE** FOR MOBILE HOMES Specifications: Electrical Rating: 24 VAC, 5 amps Pressure Regulator: Factory set @3.5" W.C. (Natural Gas),@11.0" W.C.(LP Gas) Pilot outlet: ¼" tubing Ambient temperature: -40° to 175° F Maximum inlet pressure: 7" W.C. - natural gas / 14" W.C. - LP Gas ** Convertible regulator for mobile home use. Select 3.5" W.C. natural gas or 11.0" W.C. L.P. Gas. 24 VOLT STEP-OPENING CONVERTIBLE Locke# Uni-Line Number Factory Model Inlet Size (FPT) Outlet Size (FPT) Capacity Reducer Bushings Included (NPT) ¾"x½" ½"x a " ¾"x a " Replaces L0392 720-007 7200ERC 1/2" 1/2" 150,000 120-402 AND 120-407 L0394 720-474 7200ERCS 1/2" 1/2" 150,000 120-473 AND 120-474
L
720-007
| HVAC
720 SERIES PILOT IGNITION GAS VALVES
Specifications: Electrical Rating: Power Consumption:
24 VAC, 50/60 Hz .45 amps
5 watts Class 2
NEC:
Terminal Connections:
¼" quick-connect
Pilot outlet:
¼" tubing
Ambient temperature: Maximum inlet pressure: Pressure regulator setting:
-40° to 175° F Max. 14" W.C. (1/2 PSI)
UNI-KIT
Locke#
Vendor# Factory Model
Description
L0558
720-070 72001PERS7C ½" Inlet x ¾" Outlet Size. Includes (1) ¾" to ½" reducer bushing. Pressure regulator setting is UNI-KIT. 150,000 BTU
720-070
REDUNDANT OEM VALVE This gas valve is designed for direct spark ignition, hot surface ignition & proven pilot system applications. It is equipped with redundant (pilot) & main solenoid valves that control gas flow to the main burners &/ or pilot, a field-adjustable outlet pressure regulator, & a two-position on/off switch for electrical shut-off. Specifications: Natural Gas OR LP Gas; 24 VAC; 50/60 Hz Ambient temperature: -40° F to 175° F Pressure Rating: 14" W.C. (½ PSI) max.
Capacity at 1" Pressure Drop across valve AGA Std. Nat. Gas (1,000 BTU/cu. ft.) LP Gas (2,500 BTU/cu. ft.)
Locke#
Model# Pipe Sizes Available (inches)
L0795 36E24-214 ½" x a " NPT straight through
100,000
162,000
Credit: 405-631-9756
459
www.lockesuppl .com
Made with FlippingBook