2014 Locke Supply Co.

AIR CLEANERS, ICE MACHINE SANITIZER & VENTILATORS

ENERGy RECOVERy VENTILATOR

REPLACEMENT FILTER

HUMIDIFIER HUMIDISTAT WITH BLOWER ACTIVATION

Provide proper levels of ventilation with energy savings by transferring heat and moisture between the exhaust and fresh air streams. • Includes heat/energy

transfer core, pre- filters, and fan and blower assembly.

• For use with Aprilaire Model No. 2210 and 4200 Air Cleaners (Part # 213) • Filter can be used in 2200 and 2120 air cleaners if Aprilaire 1213 upgrade kit has been installed L7152 • Factory original accordion type design for easy storage Locke# L7150 213 Filter Media L7152 1213 Model 2200 upgrade kit

• Variable fan speed control. • Easy-to-clean core assures years of trouble-free operation. • Permanent (washable) pre-filters.

• For use with Aprilaire model 110, 112, 220, 224, 400, 440, 445, 445A, 448, 500, 550, 558, 560, 560A, 568, 600, 700, 760, 760A and 768 and any other humidifier that requires 24V humidistat • Includes Control, Outdoor Sensor, Manual Mode Sticker, Installation Instructions and Owners Manual • The new Aprilaire # 60 automatic humidifier control works in conjunction with your furnace to control the operation of the humidifier. • Replaces the #58 Aprilaire Automatic Humidifier Control. Mounts on return ductwork. • The control senses indoor RH and outdoor temperature and automatically adjusts the operation time of the humidifier to provide the optimum humidity level in the home. Locke# L7154 60 Automatic Digital Humidifier control

Temperature Recovery: 0.79 Moisture Transfer Ratio: 0.26 Airflow Capacity: 150 cfm Locke# Model L7129

ER150C2004 Ventilator

REPLACEMENT FILTER

FRESH AIR VENTILATION SySTEM Designed for easy installation and works

with existing HVAC fan systems. It’s an affordable solution to ventilation, yet it offers best-in-class benefits. The Y8150A helps meet local and

L

| HVAC

• Fits models 4400, 3310 and 2410 • May also be used in models 2400 and 2140 with upgrade kit #1413 Locke# L7151 413 Filter Media

federal codes, including the new ASHRAE 62.2 standard. The intelligent algorithm calculates the amount of ventilation needed based on simple settings for each home. This “set it and forget it” program means fewer callbacks for you and optimal ventilation for the homeowner. Locke# L3635 Y8150A1009 Ventilator

WATER SOLENOID VALVE

770-1 DUAL PURPOSE AIR SWITCHES • Responds to positive, negative or differential air pressure. • Design eliminates

Locke# L7153

RP4040 water solenoid valve

“fluttering” or malfunction due to shock or vibration normally encountered with “Sail Switches.”

• Wide operating range. Locke# L1060

Model 770-1 Dual Purpose Air Switch