2014 Locke Supply Co.

GEOTHERMAL HEAT PUMPS & ACCESSORIES

GEOTEC™ GV – SERIES HIGH EFFICIENCY GEOTHERMAL/WATER SOURCE, PACKAGED STEP-CAPACITY UPFLOW HEAT PUMP — R410A Engineered Features

Steel Cabinet: Galvanized 20 gauge zinc coated steel cabinet with baked-on enamel. Multi-Capacity Two-Stage: Simple thermostatic control seamlessly stages the compressor and indoor airflow rate between full and part load capacity operation without cycling the compressor. This helps to maximize comfort, humidity control, energy efficiency and overall reduction in compressor cycling for improved system life. Step Capacity Compressor: Copeland step-capacity scroll compressors are designed for increased efficiency, quieter operation and improved reliability. R-410A Refrigerant: Designed with R-410A (HFC) non-ozone depleting refrigerant. Liquid Line Drier: Protects system against moisture. Lockout Circuit: Built-in lockout circuit resets from the room thermostat. Provides commercial quality compressor protection. High Pressure Switch: Provides additional protection for the system. Control Panel: Can be reversed to other side for installation flexibility. Low Pressure Switch: Two switches provided. Factory wired switch is for ground water applications, alternate switch is field connected for ground loop applications.

H gh Effic ency Copper Coax al Water Coil: Water to refrigerant coil is completely insulated to prevent frost build-up at low temperature operation. Indoor Air Coil: Grooved copper tubing and enhanced louvered aluminum fin for maximum heat transfer and energy efficiency. Coil is constructed with special corrosion resistant hydrophilic fin stock with 2-layer coating. Filter Rack: Factory installed with 2" MERV 6 pleated filter. Thermostatic Expansion Valve: For wide range refrigerant control (2-way operation). Domestic Hot Water Heat Exchanger: Double wall vented heat exchanger, factory installed on all models - optional GVDM-26 pump kit required for hot water heating. Water Connections: All water connections on outside of cabinet with dual side connections. Brass full swivel double o-ring connection with 1" full flow ports. Electric Heat: Slide in Electric Heater Package - up to 18KW can be field installed. Variable Speed ECM Blower Motor: • High Efficiency • Soft starting - low noise on start up • Continuous fan - will operate at 50% of rated Stage 2 airflow Mild Weather Operation: Part Load Cooling Operation will operate at 20% reduced airflow

TYPICAL INSTALLATION Unit installs upright and hooks up

conveniently to supply water system. Ideal for closet, basement, or utility room installation. Requires very little floor space. Can be installed with or without return air duct.

L

| HVAC

Ground Water Application:

Water Temp 45° to 75°

Ground Loop Application:

Temp Range 25° to 110°

Compressor

Blower Motor And Evaporator Air Filters 2" Pleated MERV 6

Min. Circuit Amps

Shipping Weight Lbs.

Voltage Range

Locke# Capacity Model

Lock Rotor Amps 230/208 HP/Speed/Type Motor Amps

Volts Rated Load

Amps 230/208

L5501 L5502 L5503 L5504

3 Ton GV38S2-AN 253-197 26 230/208 12.4/14.5

82/82

1/2 / 5 / ECM 2.5 / 2.95 20 x 25 x 2 (1)

345

4 Ton GV51S2-AN 253-197 32 230/208 17.4/20.6

96/96

1/2 / 5 / ECM 2.8 / 3.0 16 x 25 x 2 (2)

390

5 Ton GV61S2-AN 253-197 38 230/208 22.4/27.4

118/118

3/4 / 5 / ECM 3.8 / 4.1 16 x 25 x 2 (2)

440

6 Ton GV71S2-AN 253-197 41 230/208 24.7/28.5

150/150

3/4 / 5 / ECM 4.1 / 4.2 16 x 25 x 2 (2)

450

Locke# L5510

EH3GSVA-A09C Heater Package for GV27S1 or GV38S1, 1 phase-60 hz, 9.0 kW @ 240V EH3GSVA-A14C Heater Package for GV27S1 or GV38S1, 1 phase-60 hz, 13.5 kW @ 240V

L5511

L5512 EH5GSVA-A14C Heater Package for GV51S1, GV61S1 or GV71S1, 1 phase-60 hz, 13.5 kW @ 240V L5513 EH5GSVA-A18C Heater Package for GV51S1, GV61S1 or GV71S1, 1 phase-60 hz, 18.0 kW @ 240V L5507 GVDM-26

Hot water desuperheater pump module with ECM motor, 115v-60hz-1ph, 6' cord with 115V grounded plug, 5/8" OD copper water line connections, can be mounted on heat pump cabinet or adjacent wall. Loop Flow Center with Cabinet, 230V-60Hz-1Ph, 2 pump, 44 Ft. Hd. @ 16 GPM, double o-ring fittings. Loop Flow Center Kit containing: (2) 1" barbed 90° double o-ring elbows with 1/4" FPT ports and 8603-026 pressure/temperature test plugs (for heat pump connection), (2) 1" barbed straight double o-ring fittings (for loop flow center connection on heat pump side), (1) 12' section of 1” ID 150 PSI hose and (8) 1" SS hose clamps. Includes (2) 90° double o-ring quick-connect cam-lever male fittings for flush attachment to loop flow center Includes (2) 1" straight barbed quick-connect cam-lever female fittings to connect to DORCL1-90 Includes (1) Double o-ring x male garden hose adapter fitting for loop flow center (to burp/boost loop)

L5505 L5508

DORFC-2

DORLFCK-1

L5520 L5521 L5522 L5523 L5524

DORCL1-90

CLB1-S

DORGHMT 8603-027

1/4" FPT gauge adapter w/ 1/8" heavy duty probe

8603-017

FlowMeter 1-17 GPM 1" FPT

Ma n Office: 405-631-9701

350

Fax: 405-631-0585

Made with