2014 Locke Supply Co.
CONTINUOUS FLOW TANKLESS WATER HEATER SYSTEMS CONCENTRIC VENT TERMINAL KIT
CONDENSING GAS COMBINATION BOILER NATURAL GAS OR L.P.
GALVANIZED SQUARE DRAIN PANS
3" termination fitting provides for only one exit opening through wall or roof. Locke# E0859 239-44069-01 Vent Kit
For gas or electric heaters. 1" drain fitting included Locke # E1063
20922 24" x 24" x 4" Pan
1" EASY VALVE KIT
• Super condensing efficiency • Dual stainless steel heat exchangers • SCH40, 2” PVC venting up to 60’ • ½” Gas pipe up to 24’ • Automatic water filling system • Integrated controls
E
POLY TANKLESS DRAIN PAN
| WATERHEATERS
Pressure relief Valve and 1" Heating Side Locke# E1391 BCSA0563 1" Easy Valve Kit
Space Heating 18,000-120,000 BTU/H Domestic Hot Water 18,000-199,900 BTU/H
Gas Input
Flow Rate (DHW)
77°F (43°C) Temp Rise
4.5 GPM (17.0 L/m)
SEISCO POINT OF USE TANKLESS WATER HEATERS
Dimensions
17"(W) x 28"(H) x 12"(D)
Weight
84 lbs (38kg)
Installation Type
Indoor Wall-Hung
The tankless drain pan is designed to fit underneath most whole house tankless water heaters providing both water damage protection and flushing maintenance convenience. The pans are injection molded to give them superior strength and durability. Recyclable and non-toxic. They measure 21.5" W x 16" H x 13.4" D. Locke# E1066 11470 Tankless Drain pan with PVC drain fitting E1067 11476 Tankless Drain pan with CPVC drain fitting
Venting Type
Forced Draft Direct Vent
Ignition Electronic Ignition Water Pressure (Hydronic/DHW) 12-30 PSI / 15-150 PSI Natural Gas Supply Pressure (from source) 3.5"-10.5" WC Propane Gas Supply Pressure (from source) 8.0"-13.5" WC Natural Gas Manifold Pressure (min to max) -0.06" WC to -1.2" WC Propane Gas Manifold Pressure (min to max) -0.03" WC to -0.98" WC Minimum Flow Rate (DHW) 0.5 GPM (1.9 L/m)
• Activates at less than 0.30 GPM • Standard 3/4" NPT plumbing connections with no flow restrictions (adapters included to 1/2" NPT) • Fittings: 3/4" NPT (1/2" NPT adapters included) • Thermal Efficiency: 96%+ • Temperature Output (dial): 90° F to 115°F • Factory Temperature Setting: 110°F • Five Year Limited Warranty Locke# E1900 POU24-120 2.4 kw 20 amp 120 volt E1901 POU35-120 3.5 kw 30 amp 120 volt E1902 POU55-240 5.5 kw 25 amp 240 volt E1903 POU90-240 9.0 kw 40 amp 240 volt E1904 RA-28-208 28.0 kw 70 amp 208 volt E1905 RA28-240 28.0 kw 70 amp 240 volt E1906 RA32-240 32.0 kw 70 amp 240 volt
Heating Supply/ Return
1" NPT
DHW Inlet/Outlet
3/4" NPT
Connection Sizes
Gas Inlet
3/4" NPT
ALUMINUM TANKLESS DRAIN PAN
Auto Feeder 1/2" NPT Condensate Outlet 1/2" NPT
Main Supply
120V AC, 60Hz
Power Supply
Maximum Power Consumption
200W (up to 2 amperes)
Cold Rolled Carbon Steel
Casing
Primary/Secondary Heat Exchanger: Stainless Steel DHW Heat Exchanger: Stainless Steel 2” or 3" PVC, CPVC, Polypropylene 2” or 3" Special Gas Vent Type BH (Class II, A/B/C)
Materials
Heat Exchangers
The tankless drain pan is designed to fit underneath most whole house tankless water heaters providing both water damage protection and flushing maintenance convenience. Locke# E1068 11430 Tankless Aluminum Drain pan with PVC drain fitting E1069 11430 Tankless Aluminum Drain pan with CPVC drain fitting
Exhaust
Venting
Intake 2” or 3" PVC, CPVC, Polypropylene 2” or 3" Special Gas Vent Type BH (Class II, A/B/C) Vent Clearances 0" to Combustibles
Locke# E1319
NCB-240 Combo N.G. or L.P.
Credit: 405-631-9756
239
www.lockesupply.com
Made with FlippingBook